FireCADCalc

Antoine Constants from Three Vapour-Pressure Points

Antoine constants A, B and C (mmHg, °C form) fitted exactly through three measured vapour-pressure points, with a check value at another temperature.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Toluene-like pointsWater from steam tables

Point 1

Point 2

Point 3

Results

Use the constants only between the fitted temperatures; three points fix the curve exactly, so measurement errors carry straight into it.

A (for log₁₀ p in mmHg, t in °C)7.9722
B (°C, for p in mmHg)1,672.5
C (°C)228.51
Vapour pressure at the check temperature101.38kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Toluene-like points. The inputs, in the units selected above:

InputValue
Point 1: temperature50.000 °C
Point 1: vapour pressure12.300 kPa
Point 2: temperature80.000 °C
Point 2: vapour pressure47.400 kPa
Point 3: temperature110.00 °C
Point 3: vapour pressure140.60 kPa
Temperature to check95.000 °C

Applying the formula below gives:

ResultValue
A (for log₁₀ p in mmHg, t in °C)7.4187
B (°C, for p in mmHg)1,359.4
C (°C)199.26
Vapour pressure at the check temperature83.930 kPa

Open this example in the calculator and change any input.

Formula

\(\log_{10} p = A - \frac{B}{C + t}\)

Variables

Symbol Meaning SI unit
\(T_{1}\) Point 1: temperature K
\(p_{1}\) Point 1: vapour pressure Pa
\(T_{2}\) Point 2: temperature K
\(p_{2}\) Point 2: vapour pressure Pa
\(T_{3}\) Point 3: temperature K
\(p_{3}\) Point 3: vapour pressure Pa
\(T_q\) Temperature to check K
\(A\) A, for log₁₀ p with p in mmHg and t in °C -
\(B\) B, in °C for p in mmHg °C
\(C\) C, in °C °C
\(t\) temperature in °C (T − 273.15) °C
\(p\) vapour pressure in mmHg in the Antoine form mmHg
\(p(T_q)\) Vapour pressure at the check temperature Pa

Method and standards

Exact fit of the Antoine equation through three points, in the mmHg and °C form: log₁₀ p = A − B/(C + t), linearised as y t = A t + (AC − B) − C y and solved as three linear equations. Constants in other forms (bar, kPa, K, natural log) differ: convert before using them in another calculator.

Where it is used

  • Fitting your own vapour pressure data.
  • Solvent recovery design.

Common mistakes

  • Points too close together.
  • Extrapolating beyond the points.

Assumptions and limits

  • Antoine form valid over the range.
  • Nearly collinear points (an ill-conditioned fit) are rejected.

References

  • Exact three-point solution of the Antoine equation
  • linearised as y t = A t + (AC − B) − C y

Questions and answers

What do the default points describe?

A liquid boiling near 100 °C; the check at 95 °C gives about 84 kPa.

Why three points?

Antoine has three constants.

More data?

A least-squares fit over all points is better than an exact fit to three.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.