Flash Vessel Sizing (Blowdown and Condensate)

Diameter of a vertical flash vessel for blowdown or condensate from the flash steam flow and the allowable vapour velocity by the Souders–Brown equation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerFlash vessel and condensate

Inputs

Examples: Blowdown 2 t/h from 45 bar(a) to 2 bar(a), K 0.05Condensate 10 t/h from 10.5 bar(a) to 1.5 bar(a), K 0.06Blowdown 0.5 t/h from 18 bar(a) to 1.2 bar(a), K 0.05

The water is taken as saturated at this pressure (boiler drum or steam trap inlet).
Sets how much liquid carry-over is accepted. The GPSA Engineering Data Book gives about 0.1 m/s for vertical separators with a wire-mesh demister; without one about half is usual. Enter your design value.

Results

Minimum inside diameter of the vessel348.83mm
Allowable vapour velocity1.4441m/s
Flash steam560.93kg/h
Flash fraction28.046%
Flash steam volume flow496.83m³/h
Steam density in the vessel1.1290kg/m³
Water density in the vessel942.94kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Blowdown 2 t/h from 45 bar(a) to 2 bar(a), K 0.05. The inputs, in the units selected above:

InputValue
Blowdown or condensate entering2,000.0 kg/h
Pressure before flashing (absolute)45.000 bar
Flash vessel pressure (absolute)2.0000 bar
Souders–Brown velocity factor0.050000 m/s

Applying the formula below gives:

ResultValue
Minimum inside diameter of the vessel348.83 mm
Allowable vapour velocity1.4441 m/s
Flash steam560.93 kg/h
Flash fraction28.046 %
Flash steam volume flow496.83 m³/h
Steam density in the vessel1.1290 kg/m³
Water density in the vessel942.94 kg/m³

Open this example in the calculator and change any input.

Formula

\(x = \frac{h_{f,1} - h_{f,f}}{h_{fg,f}} \qquad \dot m_{fs} = x\,\dot m \qquad \dot V_v = \frac{\dot m_{fs}}{\rho_v}\)

\(u_{max} = K\sqrt{\frac{\rho_l - \rho_v}{\rho_v}} \qquad D = \sqrt{\frac{4\,\dot V_v}{\pi\,u_{max}}}\)

Variables

Symbol Meaning SI unit
\(\dot m\) blowdown or condensate entering kg/s
\(p_1\) pressure before flashing, absolute Pa
\(p_f\) flash vessel pressure, absolute Pa
\(K\) Souders–Brown velocity factor m/s
\(D\) minimum inside diameter m
\(u_{max}\) allowable vapour velocity m/s
\(\dot m_{fs}\) flash steam kg/s
\(x\) flash fraction –
\(\dot V_v\) flash steam volume flow m³/s
\(\rho_v\) steam density in the vessel kg/m³
\(\rho_l\) water density in the vessel kg/m³
\(h_{f,1}\) saturated water enthalpy before flashing J/kg
\(h_{f,f}\) saturated water enthalpy at vessel pressure J/kg
\(h_{fg,f}\) latent heat at vessel pressure J/kg

Method and standards

Flash fraction from the energy balance with FireCAD's IAPWS-IF97 saturation properties; allowable vapour velocity by the Souders–Brown equation (Souders and Brown, 1934), as used for vertical vapour–liquid separators in the GPSA Engineering Data Book.

Where it is used

  • Blowdown flash vessels and condensate flash recovery.
  • Low-pressure steam recovery to deaerators and heaters.
  • Checking an existing vessel for a higher blowdown rate.

Common mistakes

  • Using gauge pressures in the flash calculation.
  • Choosing too high a vapour velocity, which carries water over.
  • Forgetting the vent and drain sizes.

Assumptions and limits

  • Water saturated at the upstream pressure; subcooled condensate flashes less.
  • Vertical vessel, vapour flowing upward over the full cross-section.
  • The K factor is your design choice; the calculator does not check carry-over (a note appears above 0.15 m/s).
  • The diameter is the bare minimum: no design margin, inlet momentum or droplet-loading allowance is added.

References

  • Souders and Brown (1934)
  • GPSA Engineering Data Book (separator K values)
  • IAPWS R7-97(2012) IF97

Questions and answers

How do I size a flash vessel?

Find the flash steam, then the allowable vapour velocity u = K·√((ρ_l − ρ_v)/ρ_v), and the diameter that passes the steam at that velocity. 2 t/h of blowdown from 45 bar(a) to 2 bar(a) flashes 28 % (561 kg/h); with K = 0.05 m/s the velocity is 1.44 m/s and the vessel needs 349 mm.

Which K value?

It sets how much water the steam carries over. The GPSA data book gives about 0.1 m/s for vertical separators with a wire-mesh demister; vessels without one use about half. Enter your design value.

What about the height?

The calculator gives the diameter. Height comes from the inlet arrangement, the disengagement space above it and the water hold-up below, from your vessel standard.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.