Worked example
Example: 10 t/h saturated steam at 10.5 bar(a), 25 m/s, check DN150 (154.1 mm). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow | 10,000 kg/h |
| Steam pressure (absolute) | 10.500 bar |
| Steam condition | Dry saturated |
| Steam temperature (superheated only) | 250.00 °C |
| Design velocity | 25.000 m/s |
| Chosen pipe inside diameter to check (0 = skip) | 154.10 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inside diameter for the design velocity | 162.00 mm |
| Velocity in the chosen pipe | 27.628 m/s |
| Volume flow of steam | 1,855.0 m³/h |
| Specific volume of the steam | 0.18550 m³/kg |
Open this example in the calculator and change any input.
Formula
\(\dot V = \dot m\,v \qquad D = \sqrt{\frac{4\,\dot V}{\pi\,u}} \qquad u_{sel} = \frac{4\,\dot V}{\pi\,D_{sel}^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | steam flow | kg/s |
| \(p\) | steam pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated steam | – |
| \(T_s\) | steam temperature (superheated) | K |
| \(u\) | design velocity | m/s |
| \(D_{sel}\) | chosen pipe inside diameter | m |
| \(D\) | inside diameter for the design velocity | m |
| \(u_{sel}\) | velocity in the chosen pipe | m/s |
| \(\dot V\) | volume flow of steam | m³/s |
| \(v\) | specific volume of the steam | m³/kg |
Method and standards
Continuity for a full circular pipe, with the specific volume from FireCAD's IAPWS-IF97 implementation.
Where it is used
- Sizing steam mains and branches in boiler houses and process plants.
- Checking existing lines for a capacity increase.
- Sizing PRDS inlet and outlet lines.
Common mistakes
- Using the same velocity for saturated and superheated steam.
- Sizing on velocity alone when pressure drop limits a long line.
- Using gauge pressure for steam density.
Assumptions and limits
- Sizing by velocity only; check the pressure drop with the steam pipe pressure drop calculator.
- Inside diameter: outside diameter minus twice the wall thickness.
- Dry steam; wet steam needs separators and drainage.
References
- IAPWS R7-97(2012) IF97 (specific volume)
- Continuity equation
Questions and answers
How do I size a steam pipe?
Volume flow = mass flow × specific volume; area = volume flow ÷ velocity. 10 t/h of dry saturated steam at 10.5 bar(a) is 0.515 m³/s; at 25 m/s it needs a 162 mm bore, so a DN150 pipe (154.1 mm) runs at 27.6 m/s.
Which velocity should I use?
The one in your piping specification; it balances pipe cost against pressure drop, noise and erosion. The calculator does not suggest one.
Why does low-pressure steam need bigger pipes?
Its specific volume is larger: 0.46 m³/kg at 4 bar(a) against 0.19 m³/kg at 10.5 bar(a).
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.