Worked example
Example: 200 mm, 90° bend, 10 bar g, 50 L/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Internal pressure (gauge) | 10.000 bar |
| Inside diameter (or effective diameter of the bellows) | 200.00 mm |
| Bend angle (change of direction) | 90.000 ° |
| Volume flow | 180.00 m³/h |
| Fluid density | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure thrust on one end p A (expansion joint) | 31.416 kN |
| Momentum force on one end ρ Q v | 0.079418 kN |
| Resultant on the bend 2 (pA + ρQv) sin(θ/2) | 44.541 kN |
Open this example in the calculator and change any input.
Formula
\(F_p = pA, \quad F_m = \rho Q v, \quad F_R = 2(pA + \rho Q v)\sin\frac{\theta}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Internal pressure (gauge) | Pa |
| \(d\) | Inside diameter (or effective diameter of the bellows) | m |
| \(\theta\) | Bend angle (change of direction) | rad |
| \(Q\) | Volume flow | m³/s |
| \(\rho\) | Fluid density | kg/m³ |
| \(F_p\) | Pressure thrust on one end p A (expansion joint) | N |
| \(F_m\) | Momentum force on one end ρ Q v | N |
| \(F_R\) | Resultant on the bend 2 (pA + ρQv) sin(θ/2) | N |
Method and standards
Force balance on the bend control volume.
Where it is used
- Thrust blocks for buried mains.
- Anchors for expansion joints.
Common mistakes
- Using outside diameter.
- Forgetting test pressure.
Assumptions and limits
- Equal inlet and outlet sizes.
References
- Momentum equation on a pipe bend (Textbook fluid mechanics (White, Fluid Mechanics))
Questions and answers
A 200 mm, 90° bend at 10 bar g?
Pressure thrust 31.4 kN per end; resultant about 44.5 kN.
Why do expansion joints need anchors?
An unrestrained bellows pushes the pipe apart with p A.
Is momentum important?
Only at high velocity; pressure usually dominates.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.