FireCADCalc

Water Hammer Pressure Rise (Joukowsky)

Pressure surge when flow in a pipe is stopped, by the Joukowsky equation with the wave speed from liquid and pipe elasticity, and the effect of a slower valve closure.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserPump

Inputs

Examples: Steel DN200, 6 mm wall, 2 m/s stopped, 500 m, 0.5 s closureSame line, 10 s closureHDPE 160 mm, 14.6 mm wall, 1.5 m/s, 800 m, 5 s

Steel about 200 GPa; ductile iron about 170 GPa; HDPE about 1 GPa.

Results

Closing slower than 2L/a: the rise is estimated by the Michaud relation 2ρLΔv/t_c; a surge analysis gives the exact value.

Pressure wave speed1,270.0m/s
Pressure rise for rapid closure (Joukowsky)25.350bar
Head rise for rapid closure259.01m
Critical closing time (wave round trip)0.78738s
Pressure rise for the given closing time9.9800bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steel DN200, 6 mm wall, 2 m/s stopped, 500 m, 0.5 s closure. The inputs, in the units selected above:

InputValue
Bulk modulus of the liquid2.2000 GPa
Liquid density998.00 kg/m³
Pipe inside diameter200.00 mm
Pipe wall thickness6.0000 mm
Young's modulus of the pipe wall200.00 GPa
Change in flow velocity2.0000 m/s
Pipe length from the valve to the reservoir or tank500.00 m
Valve closing time0.50000 s

Applying the formula below gives:

ResultValue
Pressure wave speed1,270.0 m/s
Pressure rise for rapid closure (Joukowsky)25.350 bar
Head rise for rapid closure259.01 m
Critical closing time (wave round trip)0.78738 s
Pressure rise for the given closing time25.350 bar

Open this example in the calculator and change any input.

Formula

\(a = \sqrt{\frac{K/\rho}{1 + \frac{K D}{E e}}}\)

\(\Delta p = \rho\, a\, \Delta v, \quad \Delta H = \frac{\Delta p}{\rho g}\)

\(2L/a, \quad \Delta p_c = \frac{2 \rho L \Delta v}{t_c} \ \text{for}\ t_c > 2L/a\)

Variables

Symbol Meaning SI unit
\(K\) liquid bulk modulus Pa
\(\rho\) liquid density kg/m³
\(D\) pipe inside diameter m
\(e\) wall thickness m
\(E\) Young's modulus of the pipe Pa
\(\Delta v\) change in velocity m/s
\(L\) pipe length m
\(t_c\) valve closing time s
\(a\) wave speed m/s
\(\Delta p\) pressure rise, rapid closure Pa
\(\Delta H\) head rise m
\(2L/a\) critical closing time s
\(\Delta p_c\) pressure rise for the closing time Pa
\(g\) standard gravity m/s²

Method and standards

Stopping a liquid column sends a pressure wave along the pipe at speed a, set by the liquid's compressibility and the pipe wall's elasticity (Korteweg). The Joukowsky rise ρ a Δv applies to closures faster than the wave's round trip 2L/a; slower closures are estimated by Michaud's relation.

Where it is used

  • Setting valve closing times on pump discharges and long lines.
  • Checking pipe pressure ratings against pump trips.
  • Deciding when surge vessels or slow-closing check valves are needed.

Common mistakes

  • Ignoring the surge from a pump trip, which stops the flow as fast as a valve.
  • Using closure time from fully open; most of the flow is cut in the last part of travel.
  • Forgetting vapour-cavity collapse can exceed the Joukowsky value.

Assumptions and limits

  • Single uniform pipe, thin wall, anchored with expansion joints (restraint factor 1 in the Korteweg wave speed). A pipe anchored against axial movement or buried has a factor below 1 (about 1 − ν² for a fully anchored pipe), which gives a slightly higher wave speed and surge.
  • Column separation is not checked: when the downstream or low-pressure side of a closure falls to vapour pressure, the cavity's collapse can give a surge above the Joukowsky value.
  • Friction and cavitation not included; complex systems need a transient analysis.

References

  • Joukowsky (1898)
  • Korteweg wave speed
  • Michaud slow-closure relation

Questions and answers

How much pressure rise does stopping 2 m/s of water give?

In a DN200 steel pipe with 6 mm wall the wave speed is about 1 270 m/s, so the rise is about 25 bar (259 m of head).

How slow must a valve close to avoid it?

Slower than 2L/a, the wave's round trip: 0.79 s for 500 m in the example. Closing in 10 s cuts the rise to about 2 bar.

Why are plastic pipes gentler?

Their low modulus slows the pressure wave, so the same velocity change gives a much smaller surge.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.