Worked example
Example: Stoker 26 kg/s, PA 40 %, OFA 15 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total combustion air (wet) | 93,600 kg/h |
| Primary air share | 40.000 % |
| Over-fire air share (0 if none) | 15.000 % |
| Air temperature at the PA fan inlet | 35.000 °C |
| Air temperature at the SA fan inlet | 35.000 °C |
| Pressure at the fan inlets (absolute) | 1.0132 bar |
| Air humidity (kg water per kg dry air) | 0.013000 kg/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Primary air | 37,440 kg/h |
| Secondary air | 42,120 kg/h |
| Over-fire air | 14,040 kg/h |
| Primary air, actual volume at the PA fan | 32,938 m³/h |
| Secondary air, actual volume at the SA fan | 37,056 m³/h |
| Over-fire air, actual volume (SA fan conditions) | 12,352 m³/h |
| Secondary air share | 45.000 % |
| Air density at the PA fan | 1.1367 kg/m³ |
| Air density at the SA fan | 1.1367 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\dot m_{PA} = x_{PA}\,\dot m_a \qquad \dot m_{OFA} = x_{OFA}\,\dot m_a \qquad \dot m_{SA} = \dot m_a - \dot m_{PA} - \dot m_{OFA} \qquad x_{SA} = 1 - x_{PA} - x_{OFA}\)
\(\rho = \frac{(1+\omega)\,p}{\left(\frac{1}{M_{da}} + \frac{\omega}{M_w}\right) R\,T} \qquad \dot V_{PA} = \frac{\dot m_{PA}}{\rho_{PA}} \qquad \dot V_{SA} = \frac{\dot m_{SA}}{\rho_{SA}} \qquad \dot V_{OFA} = \frac{\dot m_{OFA}}{\rho_{SA}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_a\) | total combustion air, wet | kg/s |
| \(x_{PA}\) | primary air share | – |
| \(x_{OFA}\) | over-fire air share | – |
| \(T_{PA}\) | air temperature at the PA fan inlet | K |
| \(T_{SA}\) | air temperature at the SA fan inlet | K |
| \(p\) | pressure at the fan inlets | Pa |
| \(\omega\) | air humidity | kg/kg |
| \(\dot m_{PA}\) | primary air | kg/s |
| \(\dot m_{SA}\) | secondary air | kg/s |
| \(\dot m_{OFA}\) | over-fire air | kg/s |
| \(\dot V_{PA}\) | primary air, actual volume | m³/s |
| \(\dot V_{SA}\) | secondary air, actual volume | m³/s |
| \(\dot V_{OFA}\) | over-fire air, actual volume | m³/s |
| \(x_{SA}\) | secondary air share | – |
| \(\rho_{PA}\) | air density at the PA fan | kg/m³ |
| \(\rho_{SA}\) | air density at the SA fan | kg/m³ |
| \(M_{da}\), \(M_w\) | molar mass of dry air and water | kg/kmol |
| \(R\) | universal gas constant, 8 314.46 | J/(kmol·K) |
Method and standards
Mass split of the combustion air; humid-air densities by the ideal-gas law with the ASME PTC 4-2013 dry-air molar mass.
Where it is used
- Splitting combustion air between primary and secondary fans.
- Pulverised coal, stoker and fluidised-bed boilers.
- Fan sizing for new boilers.
Common mistakes
- Using the split of another boiler type.
- Forgetting tempering air and seal air.
- Ignoring air heater leakage on each side.
Assumptions and limits
- Over-fire air is taken from the SA fan (at SA conditions); if it has its own fan, use that fan's temperature.
- Seal air, coal-feeder air and sweep air are not split out; include them in the shares.
- Both fans are taken at the same inlet pressure; the fans' pressure rise and the air heater leakage on each side are not modelled (add leakage to the fan flows yourself).
- The shares are not checked against typical values for the firing system; they come from the boiler maker.
References
- Ideal-gas humid air density; ASME PTC 4-2013 (air composition)
Questions and answers
How is combustion air split between PA and SA?
By the firing system. A stoker might take 40 % under the grate and 15 % as over-fire air; a bubbling bed takes most of its air as fluidising (primary) air; pulverised coal uses 20–25 % as primary air to carry the coal. The share is the boiler maker's.
Why give actual volumes?
Fans are selected on the volume at their inlet. A PA fan drawing hot air at 200 °C moves about 50 % more volume per kg than one on ambient air.
Where does the total air come from?
From the combustion air flow or FD fan sizing calculator, as wet air at MCR with margin if the fans share it.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.