FireCADCalc

Primary, Secondary and Over-Fire Air Split

Primary (PA), secondary (SA) and over-fire air flows in kg/s and actual m³/h from the total combustion air and the split for grate, AFBC, CFBC or PF firing.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalPulp and paperASME PTC 4 (fired steam generators)BoilerBurner and furnaceFan and blower

Inputs

Examples: Stoker 26 kg/s, PA 40 %, OFA 15 %AFBC 40 kg/s, PA 65 %, no OFA, PA from hot air 200 °CPF 120 kg/s, PA 22 %, OFA 18 %, 0.96 bar

From the combustion air flow or FD fan sizing calculator.
Set by the firing system and the boiler maker.
Hot-air PA fans in some PF and AFBC plants take air after the air heater.

Results

Primary air93,600kg/h
Secondary air50,400kg/h
Primary air, actual volume at the PA fan126,438m³/h
Secondary air, actual volume at the SA fan44,340m³/h
Secondary air share35.000%
Air density at the PA fan0.74028kg/m³
Air density at the SA fan1.1367kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Stoker 26 kg/s, PA 40 %, OFA 15 %. The inputs, in the units selected above:

InputValue
Total combustion air (wet)93,600 kg/h
Primary air share40.000 %
Over-fire air share (0 if none)15.000 %
Air temperature at the PA fan inlet35.000 °C
Air temperature at the SA fan inlet35.000 °C
Pressure at the fan inlets (absolute)1.0132 bar
Air humidity (kg water per kg dry air)0.013000 kg/kg

Applying the formula below gives:

ResultValue
Primary air37,440 kg/h
Secondary air42,120 kg/h
Over-fire air14,040 kg/h
Primary air, actual volume at the PA fan32,938 m³/h
Secondary air, actual volume at the SA fan37,056 m³/h
Over-fire air, actual volume (SA fan conditions)12,352 m³/h
Secondary air share45.000 %
Air density at the PA fan1.1367 kg/m³
Air density at the SA fan1.1367 kg/m³

Open this example in the calculator and change any input.

Formula

\(\dot m_{PA} = x_{PA}\,\dot m_a \qquad \dot m_{OFA} = x_{OFA}\,\dot m_a \qquad \dot m_{SA} = \dot m_a - \dot m_{PA} - \dot m_{OFA} \qquad x_{SA} = 1 - x_{PA} - x_{OFA}\)

\(\rho = \frac{(1+\omega)\,p}{\left(\frac{1}{M_{da}} + \frac{\omega}{M_w}\right) R\,T} \qquad \dot V_{PA} = \frac{\dot m_{PA}}{\rho_{PA}} \qquad \dot V_{SA} = \frac{\dot m_{SA}}{\rho_{SA}} \qquad \dot V_{OFA} = \frac{\dot m_{OFA}}{\rho_{SA}}\)

Variables

Symbol Meaning SI unit
\(\dot m_a\) total combustion air, wet kg/s
\(x_{PA}\) primary air share –
\(x_{OFA}\) over-fire air share –
\(T_{PA}\) air temperature at the PA fan inlet K
\(T_{SA}\) air temperature at the SA fan inlet K
\(p\) pressure at the fan inlets Pa
\(\omega\) air humidity kg/kg
\(\dot m_{PA}\) primary air kg/s
\(\dot m_{SA}\) secondary air kg/s
\(\dot m_{OFA}\) over-fire air kg/s
\(\dot V_{PA}\) primary air, actual volume m³/s
\(\dot V_{SA}\) secondary air, actual volume m³/s
\(\dot V_{OFA}\) over-fire air, actual volume m³/s
\(x_{SA}\) secondary air share –
\(\rho_{PA}\) air density at the PA fan kg/m³
\(\rho_{SA}\) air density at the SA fan kg/m³
\(M_{da}\), \(M_w\) molar mass of dry air and water kg/kmol
\(R\) universal gas constant, 8 314.46 J/(kmol·K)

Method and standards

Mass split of the combustion air; humid-air densities by the ideal-gas law with the ASME PTC 4-2013 dry-air molar mass.

Where it is used

  • Splitting combustion air between primary and secondary fans.
  • Pulverised coal, stoker and fluidised-bed boilers.
  • Fan sizing for new boilers.

Common mistakes

  • Using the split of another boiler type.
  • Forgetting tempering air and seal air.
  • Ignoring air heater leakage on each side.

Assumptions and limits

  • Over-fire air is taken from the SA fan (at SA conditions); if it has its own fan, use that fan's temperature.
  • Seal air, coal-feeder air and sweep air are not split out; include them in the shares.
  • Both fans are taken at the same inlet pressure; the fans' pressure rise and the air heater leakage on each side are not modelled (add leakage to the fan flows yourself).
  • The shares are not checked against typical values for the firing system; they come from the boiler maker.

References

  • Ideal-gas humid air density; ASME PTC 4-2013 (air composition)

Questions and answers

How is combustion air split between PA and SA?

By the firing system. A stoker might take 40 % under the grate and 15 % as over-fire air; a bubbling bed takes most of its air as fluidising (primary) air; pulverised coal uses 20–25 % as primary air to carry the coal. The share is the boiler maker's.

Why give actual volumes?

Fans are selected on the volume at their inlet. A PA fan drawing hot air at 200 °C moves about 50 % more volume per kg than one on ambient air.

Where does the total air come from?

From the combustion air flow or FD fan sizing calculator, as wet air at MCR with margin if the fans share it.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.