Worked example
Example: Pipeline gas 50 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Methane | 90.000 % |
| Ethane | 5.0000 % |
| Propane | 2.0000 % |
| Carbon dioxide | 1.0000 % |
| Nitrogen | 2.0000 % |
| Pressure (absolute) | 50.000 bar |
| Temperature | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pseudo-critical temperature | -73.418 °C |
| Pseudo-critical pressure | 46.093 bar |
| Compressibility factor | 0.88511 |
| Gas density | 41.311 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(T_{pc} = \sum y_i T_{c,i}, \quad p_{pc} = \sum y_i p_{c,i}, \quad t = \frac{T_{pc}}{T}, \quad p_{pr} = \frac{p}{p_{pc}}\)
\(A = 0.06125\,t\,e^{-1.2(1-t)^2}, \quad B = 14.76t - 9.76t^2 + 4.58t^3, \quad C = 90.7t - 242.2t^2 + 42.4t^3, \quad D = 2.18 + 2.82t\)
\(-A p_{pr} + \frac{y + y^2 + y^3 - y^4}{(1-y)^3} - B y^2 + C y^{D} = 0, \quad Z = \frac{A p_{pr}}{y}, \quad \rho = \frac{p M}{Z R T}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_{CH_4}\) | Methane | - |
| \(y_{C_2H_6}\) | Ethane | - |
| \(y_{C_3H_8}\) | Propane | - |
| \(y_{CO_2}\) | Carbon dioxide | - |
| \(y_{N_2}\) | Nitrogen | - |
| \(p\) | Pressure (absolute) | Pa |
| \(T\) | Temperature | K |
| \(T_{pc}\) | Pseudo-critical temperature | K |
| \(p_{pc}\) | Pseudo-critical pressure | Pa |
| \(Z\) | Compressibility factor | - |
| \(\rho\) | Gas density | kg/m³ |
| \(y_i\) | mole fraction of component i | - |
| \(T_{c,i}\), \(p_{c,i}\) | critical temperature and pressure of component i (NIST) | K, Pa |
| \(t\) | reciprocal pseudo-reduced temperature, T_pc/T | - |
| \(p_{pr}\) | pseudo-reduced pressure | - |
| \(A\), \(B\), \(C\), \(D\) | Hall–Yarborough coefficients | - |
| \(y\) | reduced density, the root of the equation | - |
| \(M\) | molar mass of the gas, Σ y_i M_i | kg/kmol |
| \(R\) | universal gas constant | J/(kmol·K) |
Method and standards
Kay's rule gives the pseudo-critical temperature and pressure as mole-fraction averages of the components' critical constants; the Hall–Yarborough equation (a fit to the Standing–Katz chart) is solved for the reduced density y, taking the smallest root (the gas root), and Z = A p_pr / y.
Where it is used
- Gas metering and pipeline checks.
- Gas train sizing.
Common mistakes
- Mole fractions not adding to 100 %.
Assumptions and limits
- Sweet natural gas; a warning is given above 2 % CO₂ (no Wichert–Aziz correction).
- The Hall–Yarborough equation is solved by scanning upwards for the first sign change and bisecting it; the result is rejected if it does not converge.
- Only methane, ethane, propane, CO₂ and N₂ are inputs. Butanes and heavier must be lumped into propane, a rough approximation; for a rich gas use a full equation of state such as AGA 8.
- CO₂ above 2 % gives a warning; the fractions are not limited.
References
- Hall and Yarborough (1973) equation of state on Standing–Katz Z; Kay's rule pseudo-critical properties; critical constants from the NIST Chemistry WebBook
Questions and answers
Why Z?
Real gas occupies less volume than ideal at pressure; meters and pipelines must correct for it.
Kay's rule?
Mole-fraction-weighted critical temperature and pressure of the mixture.
Range?
Hall–Yarborough fits the Standing–Katz chart for 1.05 ≤ T_pr ≤ 3 and p_pr up to about 20.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.