Flue Gas and Air Properties

Density, specific heat, enthalpy, viscosity, thermal conductivity and Prandtl number of a flue gas or air mixture at temperature, from NIST data and kinetic-theory mixing rules.

Thermal power plantRefinery and petrochemicalChemical and fertiliserThermic fluid heatingBurner and furnaceStack and chimney

Inputs

Examples: Coal flue gas, 150 °CNatural gas flue gas, 120 °CDry air, 300 K

Composition by volume (wet)

Results

Molar mass27.703kg/kmol
Normal density (0 °C, 101.325 kPa)1.2360kg/m³
Density at T and p0.85873kg/m³
Specific heat capacity at T1.1236kJ/(kg·K)
Mean specific heat 25 °C → T1.1137kJ/(kg·K)
Enthalpy above 25 °C105.80kJ/kg
Dynamic viscosity2.0085e-05Pa·s
Kinematic viscosity2.3389e-05m²/s
Thermal conductivity0.029154W/(m·K)
Prandtl number0.77411

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal flue gas, 150 °C. The inputs, in the units selected above:

InputValue
Gas temperature150.00 °C
Absolute pressure1.0132 bar
Oxygen (O2)4.0000 %
Nitrogen (N2)74.800 %
Carbon dioxide (CO2)13.000 %
Water vapour (H2O)8.0000 %
Sulphur dioxide (SO2)0.20000 %
Carbon monoxide (CO)0 %
Hydrogen (H2)0 %
Argon (Ar)0 %

Applying the formula below gives:

ResultValue
Molar mass29.525 kg/kmol
Normal density (0 °C, 101.325 kPa)1.3173 kg/m³
Density at T and p0.85031 kg/m³
Specific heat capacity at T1.0655 kJ/(kg·K)
Mean specific heat 25 °C → T1.0500 kJ/(kg·K)
Enthalpy above 25 °C131.25 kJ/kg
Dynamic viscosity2.2064e-05 Pa·s
Kinematic viscosity2.5949e-05 m²/s
Thermal conductivity0.030990 W/(m·K)
Prandtl number0.75861

Open this example in the calculator and change any input.

Formula

\(M = \sum_i y_i M_i \qquad \rho = \frac{p\,M}{R\,T} \qquad \rho_n = \frac{M}{V_m} \qquad c_p = \frac{\sum_i y_i\,C_{p,i}(T)}{M} \qquad h = \int_{T_{ref}}^{T} c_p\,dT \qquad \bar c_p = \frac{h}{T - T_{ref}}\)

Shomate heat capacity per species, \(t = T/1000\):

\(C_{p,i} = A + Bt + Ct^2 + Dt^3 + \frac{E}{t^2}\)

Sutherland viscosity per species and Wilke's mixing rule:

\(\mu_i = \mu_{0,i}\left(\frac{T}{T_{0,i}}\right)^{3/2}\frac{T_{0,i} + S_i}{T + S_i} \qquad \mu = \sum_i \frac{y_i\,\mu_i}{\sum_j y_j\,\Phi_{ij}} \qquad \Phi_{ij} = \frac{\left[1 + (\mu_i/\mu_j)^{1/2}(M_j/M_i)^{1/4}\right]^2}{\sqrt{8\,(1 + M_i/M_j)}}\)

Eucken conductivity per species (water vapour: the IAPWS 2011 dilute-gas value instead) and the Mason–Saxena form of the Wassiljewa equation (same \(\Phi_{ij}\)):

\(k_i = \mu_i\left(c_{p,i} + \frac{5}{4}\frac{R}{M_i}\right) \qquad k = \sum_i \frac{y_i\,k_i}{\sum_j y_j\,\Phi_{ij}} \qquad \nu = \frac{\mu}{\rho} \qquad Pr = \frac{c_p\,\mu}{k}\)

Variables

Symbol Meaning SI unit
\(T\) gas temperature K
\(p\) absolute pressure Pa
\(y_i\) volume (mole) fraction of species i: \(y_{O_2}\), \(y_{N_2}\), \(y_{CO_2}\), \(y_{H_2O}\), \(y_{SO_2}\), \(y_{CO}\), \(y_{H_2}\), \(y_{Ar}\) –
\(M_i\), \(M\) molar mass of species i and of the mixture kg/kmol
\(R\) universal gas constant, 8 314.46 J/(kmol·K)
\(V_m\) molar volume at 0 °C and 101.325 kPa, 22.414 m³/kmol
\(\rho_n\) density at normal conditions kg/Nm³
\(\rho\) density at \(T\) and \(p\) kg/m³
\(C_{p,i}\) molar heat capacity of species i J/(mol·K)
\(c_p\) specific heat capacity of the mixture at \(T\) J/(kg·K)
\(\bar c_p\) mean specific heat between 25 °C and \(T\) J/(kg·K)
\(h\) enthalpy above 25 °C J/kg
\(\mu_i\), \(\mu\) dynamic viscosity of species i and of the mixture Pa·s
\(\nu\) kinematic viscosity m²/s
\(k_i\), \(k\) thermal conductivity of species i and of the mixture W/(m·K)
\(Pr\) Prandtl number –
\(T_{ref}\) reference temperature for enthalpy, 298.15 K

Method and standards

The same formulations FireCAD uses in its boiler design software: NIST-JANAF Shomate polynomials for heat capacity (NIST Chemistry WebBook), Sutherland's law for each species' viscosity, Wilke's 1950 rule for the mixture viscosity, the Eucken relation for each species' conductivity except water vapour, whose conductivity is the dilute-gas term of the IAPWS 2011 formulation (R15-11), and the Wassiljewa equation with Mason–Saxena coefficients for the mixture conductivity. Enthalpy is the numerical integral (composite Simpson rule, steps of 10 K or less) of the Shomate heat capacity from 25 °C, the ASME PTC 4 reference temperature.

Where it is used

  • Flue gas and air properties for fan, duct and heat-transfer calculations.
  • Gas mixtures for combustion and process work.
  • Checking property values in vendor data.

Common mistakes

  • Using air properties for flue gas.
  • Mixing mole and mass fractions.
  • Ignoring water vapour in the gas.

Assumptions and limits

  • Ideal gas (fine for flue gas and air below about 20 bar); a warning appears above 20 bar.
  • 250–2 500 K. Water vapour heat capacity below 500 K extrapolates the NIST fit by less than 1 %; the SO₂, CO, CO₂, H₂ and Ar fits start at 298 K and are extrapolated slightly below it (a note appears).
  • Transport mixing rules are accurate to a few per cent for viscosity; the mixture conductivity of water-rich gas is within a few per cent; they are not valid for condensing gas. A warning is given when the water vapour partial pressure exceeds the IAPWS-IF97 saturation pressure at the gas temperature (below the dew point).

References

  • NIST-JANAF Shomate heat capacities
  • Sutherland viscosity
  • Wilke (1950) mixing rule
  • Eucken relation
  • IAPWS R15-11 (2011) dilute-gas conductivity of water vapour
  • Mason–Saxena mixing

Questions and answers

Which composition should I enter, wet or dry?

Wet, as the gas actually flows through the heat transfer surfaces and fans. The combustion calculator gives the wet composition; an analyser gives dry, which you must correct for the water vapour.

Why does density fall with temperature but viscosity rise?

Gas density follows the ideal-gas law, ρ ∝ 1/T. Gas viscosity comes from molecular momentum exchange, which increases with molecular speed and therefore with temperature, roughly as T^0.7.

How accurate are the mixing rules?

Wilke's rule for viscosity is within a few per cent for combustion gases away from condensation. The Eucken form is not used for water vapour, where it runs 10–25 % high; its conductivity is the IAPWS 2011 dilute-gas value instead. The Shomate heat capacities are NIST fits accurate to better than 0.5 %.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.