FireCADCalc

Fuel Gas Pipe Pressure Drop (Isothermal)

Outlet pressure and pressure drop of a natural gas or fuel gas line by the isothermal compressible-flow equation with the Colebrook friction factor.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalPulp and paperFuel oil and gas systemBurner and furnace

Inputs

Examples: NG 1000 Nm³/h, 4 bar(a), 100 mm, 500 mNG 300 Nm³/h, 1.5 bar(a), 50 mm, 200 mNG 5000 Nm³/h, 10 bar(a), 150 mm, 2 km

About 16–18.5 kg/kmol for natural gas; from the gas analysis.

Results

Pressure drop above 10 % of the inlet pressure: check the regulator and burner pressures still work.

The outlet velocity, 38 m/s, is high: noise and erosion; consider a larger pipe.

Outlet pressure (absolute)1.1132bar
Pressure drop38.679kPa
Inlet velocity27.908m/s
Outlet velocity37.605m/s
Reynolds number142,629
Darcy friction factor0.021053

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: NG 1000 Nm³/h, 4 bar(a), 100 mm, 500 m. The inputs, in the units selected above:

InputValue
Gas flow at normal conditions1,000.0 Nm³/h
Molar mass of the gas17.400 kg/kmol
Gas dynamic viscosity1.1000e-05 Pa·s
Inlet pressure (absolute)4.0000 bar
Gas temperature20.000 °C
Pipe inside diameter102.30 mm
Pipe length (with fittings as equivalent length)500.00 m
Pipe roughness0.046000 mm

Applying the formula below gives:

ResultValue
Outlet pressure (absolute)3.8911 bar
Pressure drop10.889 kPa
Inlet velocity9.1876 m/s
Outlet velocity9.4447 m/s
Reynolds number243,989
Darcy friction factor0.018223

Open this example in the calculator and change any input.

Formula

\(G = \frac{\dot V_n\,\rho_n}{\pi D^2/4} \qquad Re = \frac{G\,D}{\mu} \qquad f = f_{Colebrook}(Re, \varepsilon/D)\)

\(p_1^2 - p_2^2 = \frac{G^2\,R\,T}{M}\left(\frac{f\,L}{D} + 2\ln\frac{p_1}{p_2}\right) \qquad v_1 = \frac{G}{\rho_1} \qquad v_2 = \frac{G}{\rho_2}\)

Variables

Symbol Meaning SI unit
\(\dot V_n\) gas flow at normal conditions Nm³/s
\(M\) molar mass of the gas kg/kmol
\(\mu\) dynamic viscosity Pa·s
\(p_1\) inlet pressure, absolute Pa
\(T\) gas temperature K
\(D\) pipe inside diameter m
\(L\) pipe length with equivalent length of fittings m
\(\varepsilon\) pipe roughness m
\(p_2\) outlet pressure, absolute Pa
\(\Delta p\) pressure drop Pa
\(v_1\) inlet velocity m/s
\(v_2\) outlet velocity m/s
\(\rho_2\) density at outlet conditions kg/m³
\(Re\) Reynolds number –
\(f\) Darcy friction factor –
\(G\) mass flux kg/(m²·s)
\(\rho_n\), \(\rho_1\) density at normal and at inlet conditions kg/m³
\(R\) universal gas constant J/(kmol·K)

Method and standards

Steady isothermal flow of an ideal gas in a constant-area pipe with the Darcy friction factor from the Colebrook–White equation (FireCAD Friction); the outlet pressure is found by bracketed root solving.

Where it is used

  • Sizing gas supply lines from the meter station to boilers and furnaces.
  • Checking pressure at the burner gas train inlet.
  • Long gas headers in process plants.

Common mistakes

  • Using gauge pressures in a squared-pressure equation.
  • Leaving out fittings and valves.
  • Using normal density in the velocity check.

Assumptions and limits

  • Isothermal ideal gas (Z = 1); horizontal pipe; flow below choking. Above about 10 bar natural gas departs from Z = 1 and a warning appears.
  • The friction factor uses Colebrook in the 2300–4000 transition range (conservative).
  • Normal volumes are at 0 °C and 101.325 kPa; scfm is converted to the US standard cubic foot (60 °F, 14.696 psia).
  • Isothermal flow chokes when the outlet pressure falls to \(G\sqrt{RT/M}\) (velocity \(\sqrt{RT/M}\)); if the equation has no solution above that pressure, the line is reported as choked.

References

  • Isothermal compressible flow in pipes (Darcy–Weisbach form)
  • Colebrook–White friction factor

Questions and answers

How do I calculate gas pipeline pressure drop?

With the isothermal flow equation, which allows for the gas expanding as pressure falls. 1000 Nm³/h of natural gas at 4 bar(a) through 500 m of 100 mm pipe loses 10.9 kPa; the gas enters at 9.2 m/s.

Can I use the liquid (Darcy) formula?

Only for small pressure drops (under about 10 % of the inlet pressure) using an average density; the isothermal equation is right for any drop short of choking.

What molar mass for natural gas?

From the gas analysis; typical pipeline gas is 16–18.5 kg/kmol (relative density 0.56–0.64).

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.