Excess Air from Flue Gas O₂

Excess air and air ratio from the O₂ reading of a flue gas analyser: the quick formula, the exact value for the fuel, and the N₂-balance value with CO₂ and CO.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalThermic fluid heatingPulp and paperASME PTC 4 (fired steam generators)BoilerBurner and furnaceStack and chimneyBoiler attendant and boiler operator examinations

Inputs

Examples: Indian coal at 4 % O2Fuel oil at 3 % O2, CO2 13.2 %, CO 50 ppmNatural gas (methane) at 3 % O2, CO 20 ppmBagasse at 6 % O2, CO2 14 %, CO 400 ppm

Analyser readings, dry basis

Ultimate analysis, as fired, by mass

Results

Excess air for this fuel39.654%
Air ratio (1 + EA)1.3965
Excess air by the quick formula O₂/(20.95 − O₂)40.134%
Excess air from O₂, CO₂ and CO (N₂ balance)39.313%
CO₂ in dry flue gas at stoichiometric combustion20.033%
CO₂ in dry flue gas expected at this O₂14.307%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal at 4 % O2. The inputs, in the units selected above:

InputValue
O₂ in dry flue gas4.0000 %
CO in dry flue gas150.00 ppm
CO₂ in dry flue gas (0 = not measured)0 %
Carbon45.000 %
Hydrogen3.5000 %
Oxygen5.0000 %
Nitrogen1.0000 %
Sulphur0.50000 %
Ash35.000 %
Moisture10.000 %

Applying the formula below gives:

ResultValue
Excess air for this fuel22.852 %
Air ratio (1 + EA)1.2285
Excess air by the quick formula O₂/(20.95 − O₂)23.599 %
CO₂ in dry flue gas at stoichiometric combustion18.159 %
CO₂ in dry flue gas expected at this O₂14.699 %

Open this example in the calculator and change any input.

Formula

Quick formula (dry O₂, CO neglected):

\(EA_s = \frac{O_{2,dry}}{0.2095 - O_{2,dry}}\)

Exact for the fuel. Per kg of fuel, \(a\) kmol of air is stoichiometric and \(D_0\) kmol of dry gas is formed at stoichiometric combustion; each kmol of extra air adds one kmol of dry gas:

\(O_{2,dry} = \frac{0.2095\,EA\,a}{D_0 + EA\,a} \;\Rightarrow\; EA = \frac{O_{2,dry}\,D_0}{a\,(0.2095 - O_{2,dry})} \qquad \lambda = 1 + EA\)

\(a = \frac{1}{0.2095}\left(\frac{C}{12.011} + \frac{H}{4.032} + \frac{S}{32.06} - \frac{O}{31.998}\right) \qquad D_0 = \frac{C}{12.011} + \frac{S}{32.06} + \frac{N}{28.014} + 0.7905\,a\)

\(CO_{2,max} = \frac{C/12.011 + 0.0004\,a}{D_0} \qquad CO_{2,calc} = \frac{C/12.011 + 0.0004\,a\,(1+EA)}{D_0 + EA\,a}\)

N₂ balance with CO (ASME PTC 4-2013 form):

\(EA_{N_2} = \frac{O_{2,dry} - CO_{dry}/2}{\tfrac{0.2095}{0.7905}\,N_2 - (O_{2,dry} - CO_{dry}/2)} \qquad N_2 = 1 - O_{2,dry} - CO_{2,dry} - CO_{dry}\)

Variables

Symbol Meaning SI unit
\(O_{2,dry}\) O₂ in dry flue gas, by volume –
\(CO_{dry}\) CO in dry flue gas –
\(CO_{2,dry}\) CO₂ in dry flue gas (0 = not measured) –
\(C\), \(H\), \(O\), \(N\), \(S\) carbon, hydrogen, oxygen, nitrogen, sulphur in the fuel as fired –
\(A\) ash –
\(M\) moisture –
\(EA\) excess air for this fuel –
\(\lambda\) air ratio –
\(EA_s\) excess air by the quick formula –
\(EA_{N_2}\) excess air by the N₂ balance with CO₂ and CO –
\(CO_{2,max}\) CO₂ in dry flue gas at stoichiometric combustion –
\(CO_{2,calc}\) CO₂ in dry flue gas this fuel gives at the O₂ reading –
\(a\) stoichiometric dry air per kg of fuel kmol/kg
\(D_0\) dry flue gas per kg of fuel at stoichiometric combustion kmol/kg
\(N_2\) nitrogen (and argon) in dry flue gas by difference –

Method and standards

Mole balance on the dry flue gas with exact molar ratios (IUPAC atomic weights) and the ASME PTC 4-2013 air composition (20.95 % O₂, 79.05 % "atmospheric nitrogen" including argon and CO₂). The N₂-balance value is the form of ASME PTC 4-2013 for excess air from a full Orsat-type analysis. For natural gas enter the analysis by mass: methane is 74.9 % carbon and 25.1 % hydrogen.

Where it is used

  • Daily combustion control from the O₂ analyser on boilers and furnaces.
  • Setting the O₂ trim set point for a fuel.
  • Efficiency tests, where excess air sets the dry flue gas loss.

Common mistakes

  • Using a wet O₂ reading in a dry-basis formula: zirconia probes read wet, extractive analysers usually dry.
  • Using the simple rule 21/(21 − O₂) for every fuel: it ignores the fuel's own composition.
  • Reading O₂ after air heater or duct leakage and treating it as furnace excess air.

Assumptions and limits

  • Analyser readings on a dry basis (extractive analyser with a cooler). Convert wet readings first with the flue gas analyser converter.
  • The fuel-specific value assumes complete combustion; with CO above about 1 000 ppm use the N₂-balance value.
  • Air in-leakage upstream of the probe counts as excess air.
  • Ash and moisture enter only the check that the analysis sums to 100 %; they do not change the excess air. An invalid analysis blocks all outputs, including the quick formula.
  • The fuel-specific value ignores CO; the N₂ balance counts fuel nitrogen and any SO₂ left in the dry gas as air nitrogen, a small error for most fuels.

References

  • ASME PTC 4-2013 (air composition, N₂ balance)
  • IUPAC atomic weights

Questions and answers

What is the formula for excess air from O₂?

The quick formula is EA = O₂/(20.95 − O₂), with O₂ in % on a dry basis. At 3 % O₂ it gives 16.7 %. It is exact only when a mole of dry flue gas replaces each mole of O₂ burnt, which is nearly true for coal and not for natural gas.

Why does natural gas give less excess air than the quick formula?

Burning methane forms water, which leaves the dry gas. The dry flue gas is smaller than the air, so a given O₂ reading means less excess air. At 3 % O₂ methane has 15.0 % excess air, not 16.7 %.

When should I use the N₂-balance value?

When the analyser also reads CO₂ and CO, and especially when CO is high. The N₂ balance of ASME PTC 4 takes the oxygen still needed to burn the CO into account.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.