Worked example
Example: 10 kg/cm² g, 200 x 200 mm pitch, 30 mm stays, 400 x 300 manhole. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Working pressure | 9.8066 bar g |
| Horizontal pitch of the stays | 200.00 mm |
| Vertical pitch of the stays | 200.00 mm |
| Stay diameter (at the root of the thread) | 30.000 mm |
| Allowable stress in the stay | 75.000 MPa |
| Manhole major axis | 400.00 mm |
| Manhole minor axis | 300.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Plate area carried by one stay | 0.040000 m² |
| Load on one stay | 39.227 kN |
| Stress in the stay | 55.494 MPa |
| Smallest stay diameter for the allowable stress | 25.806 mm |
| Manhole area | 0.094248 m² |
| Total load on the manhole door | 92.425 kN |
Open this example in the calculator and change any input.
Formula
\(F_s = (p - p_{atm})\, p_h\, p_v, \quad \sigma = \frac{F_s}{\pi d^2 / 4}, \quad d_{min} = \sqrt{\frac{4 F_s}{\pi \sigma_a}}\)
\(F_m = (p - p_{atm})\, \frac{\pi a b}{4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Working pressure | Pa |
| \(p_h\) | Horizontal pitch of the stays | m |
| \(p_v\) | Vertical pitch of the stays | m |
| \(d\) | Stay diameter (at the root of the thread) | m |
| \(\sigma_a\) | Allowable stress in the stay | Pa |
| \(a\) | Manhole major axis | m |
| \(b\) | Manhole minor axis | m |
| \(A_s\) | Plate area carried by one stay | m² |
| \(F_s\) | Load on one stay | N |
| \(\sigma\) | Stress in the stay | Pa |
| \(d_{min}\) | Smallest stay diameter for the allowable stress | m |
| \(A_m\) | Manhole area | m² |
| \(F_m\) | Total load on the manhole door | N |
Method and standards
Each stay supports the rectangle of plate around it; the manhole door carries the pressure on its whole elliptical area.
Worked example
Stays are pitched 200 mm × 200 mm on a flat plate at 10 kg/cm² g; the stays are 30 mm at the thread root.
- Area per stay = 20 cm × 20 cm = 400 cm²
- Load = 10 kg/cm² × 400 cm² = 4000 kgf = 39.2 kN
- Stress = 39 227 N / (π × 30²/4 mm²) = 55.5 N/mm²
Where it is used
- Boiler attendant and operator examinations.
- Understanding why flat surfaces of boilers need stays.
- Manhole and mudhole door handling.
Common mistakes
- Using absolute pressure.
- Using the outside thread diameter instead of the root.
- Forgetting that pressure acts on the whole door area.
Assumptions and limits
- Stay area not deducted from the supported area.
- The manhole load is the pressure on the a × b ellipse you enter: for an internal door the pressure acts out to the gasket line, so enter the axes at the gasket (not the clear opening) for the load the door and its studs carry.
- No code check of plate or stay; a warning is given only when the stay stress exceeds the allowable stress entered.
References
- Pressure × supported area (statics, textbook)
Questions and answers
What load does a stay carry at 10 kg/cm² g with 200 mm × 200 mm pitch?
39.2 kN (4000 kgf). In a 30 mm stay that is 55.5 MPa; for 75 MPa allowable the stay needs at least 25.8 mm at the root.
What load is on a 400 × 300 mm manhole door?
The area is 0.0942 m², so 92.4 kN (9.4 tonnes-force) at 10 kg/cm² g: why the door sits inside, pressed onto its seat.
Is plate thickness checked?
No; flat-plate thickness between stays follows the code's formulas.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.