FireCADCalc

Co-Firing: Heat Share and Blended Fuel Cost

Heat input from each of two fuels fired together, their shares of heat, and the blended fuel cost per GJ, from rates, calorific values and prices.

Process steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: Bagasse with coalHusk only

Results

Total heat input30.000MW
Fuel 1 share of heat100.00%
Fuel 2 share of heat0%
Blended cost per GJ333.33

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bagasse with coal. The inputs, in the units selected above:

InputValue
Fuel 1 rate (e.g. bagasse)30.000 t/h
Fuel 1 GCV, as fired9,600.0 kJ/kg
Fuel 1 price per tonne1,800.0 -
Fuel 2 rate (e.g. coal)4.0000 t/h
Fuel 2 GCV, as fired23,000 kJ/kg
Fuel 2 price per tonne9,000.0 -

Applying the formula below gives:

ResultValue
Total heat input105.56 MW
Fuel 1 share of heat75.789 %
Fuel 2 share of heat24.211 %
Blended cost per GJ236.84

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_1 GCV_1 + \dot m_2 GCV_2, \quad s_1 = \frac{\dot m_1 GCV_1}{\dot Q}, \quad s_2 = \frac{\dot m_2 GCV_2}{\dot Q}\)

\(c_{GJ} = \frac{(\dot m_1 c_1 + \dot m_2 c_2)/1000\ \text{kg/t}}{\dot Q} \times 10^9\ \text{J/GJ}\)

Variables

Symbol Meaning SI unit
\(\dot m_1\) Fuel 1 rate (e.g. bagasse) kg/s
\(GCV_1\) Fuel 1 GCV J/kg
\(c_1\) Fuel 1 price per tonne -
\(\dot m_2\) Fuel 2 rate (e.g. coal) kg/s
\(GCV_2\) Fuel 2 GCV J/kg
\(c_2\) Fuel 2 price per tonne -
\(\dot Q\) Total heat input W
\(s_1\) Fuel 1 share of heat -
\(s_2\) Fuel 2 share of heat -
\(c_{GJ}\) Blended cost per GJ -

Method and standards

Energy balance.

Where it is used

  • Off-season fuel planning.
  • Fuel purchase decisions.

Common mistakes

  • Net and gross values mixed.

Assumptions and limits

  • Steady firing.
  • Each GCV must be on the as-fired basis of its own fuel rate; mixing an as-fired value with a dry one distorts the heat shares.

References

  • Energy balance on gross calorific values

Questions and answers

Why heat share, not mass share?

Coal carries more than twice the heat of wet bagasse per tonne.

Currency?

Any, as long as both prices use the same one.

Efficiency changes with the mix?

Yes: compare cost per tonne of steam with each mix's efficiency.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.