Boiler Start-up Heat, Time and Heating Rate

Heat to bring a boiler's water and steel from cold to working pressure, the time it takes at a start-up firing rate, and the average heating rate (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Shell boiler: 12 t water, 25 t steel, cold 30 °C to 10.5 bar(a), 2 MW firing at 60 %Water-tube 50 t/h: 40 t water, 300 t steel, 30 °C to 66 bar(a), 10 MW at 50 %Warm start: 12 t water, 25 t steel, 90 °C to 10.5 bar(a), 1.5 MW at 60 %

Carbon steel is about 0.45–0.52 kJ/(kg·K) over this range.

Results

Compare the heating rate with the boiler maker's start-up curve: thick drums and headers limit how fast the saturation temperature may rise.

Time to reach working pressure1.8015h
Average heating rate51.079°C/h
Heat needed5.8367GJ
Of which to the water4.7325GJ
Of which to the steel1.1042GJ
Saturation temperature at working pressure182.02°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Shell boiler: 12 t water, 25 t steel, cold 30 °C to 10.5 bar(a), 2 MW firing at 60 %. The inputs, in the units selected above:

InputValue
Water in the boiler12.000 t
Pressure-part steel heated with the water25.000 t
Mean specific heat of the steel0.48000 kJ/(kg·K)
Starting temperature (water and steel)30.000 °C
Working pressure (absolute)10.500 bar
Start-up firing rate (fuel heat input)2,000.0 kW
Share of the firing heat that reaches water and steel60.000 %

Applying the formula below gives:

ResultValue
Time to reach working pressure2.2151 h
Average heating rate68.629 °C/h
Heat needed9.5691 GJ
Of which to the water7.7449 GJ
Of which to the steel1.8242 GJ
Saturation temperature at working pressure182.02 °C

Open this example in the calculator and change any input.

Formula

\(Q_w = M_w\,\left[h_f(p) - h(p, T_0)\right] \qquad Q_m = M_m\,c_m\,(T_{sat} - T_0) \qquad Q = Q_w + Q_m\)

\(t = \frac{Q}{\eta_s\,\dot Q_f} \qquad \dot T = \frac{T_{sat} - T_0}{t}\)

Variables

Symbol Meaning SI unit
\(M_w\) water in the boiler kg
\(M_m\) steel heated with the water kg
\(c_m\) mean specific heat of the steel J/(kg·K)
\(T_0\) starting temperature K
\(p\) working pressure, absolute Pa
\(\dot Q_f\) start-up firing rate W
\(\eta_s\) share of firing heat reaching water and steel –
\(t\) time to working pressure s
\(\dot T\) average heating rate K/s
\(Q\) heat needed J
\(Q_w\) heat to the water J
\(Q_m\) heat to the steel J
\(T_{sat}\) saturation temperature at working pressure K
\(h_f\), \(h\) water enthalpies (IF97) J/kg

Method and standards

Energy balance of the water and steel from the starting temperature to saturation at working pressure; water enthalpies from FireCAD's IAPWS-IF97. Steam vented during start-up and refractory heat are not included.

Where it is used

  • Planning start-up times and fuel.
  • Comparing cold, warm and hot starts.
  • Checking firing rate against the maker's heating curve.

Common mistakes

  • Forgetting the steel and refractory, which can need as much heat as the water.
  • Taking the start-up efficiency equal to full-load efficiency.
  • Firing faster than the allowed temperature rise.

Assumptions and limits

  • Water mass constant; uniform temperature of water and steel; no venting or refractory heat.
  • The heating rate is an average from \(T_0\) to \(T_{sat}\). The saturation temperature does not rise linearly in time, and the boiler maker's limit applies to the instantaneous rate, which can be higher than the average.

References

  • IAPWS R7-97(2012) IF97
  • first law of thermodynamics

Questions and answers

How long does a boiler take to start from cold?

Heat needed divided by the useful firing rate. A shell boiler with 12 t of water and 25 t of steel from 30 °C to 10.5 bar(a) needs 9.6 GJ; at 2 MW firing with 60 % reaching the boiler that is 2.2 hours, an average rise of 69 °C/h.

Why not fire harder?

Thick drums, shells and headers heat from the inside; fast heating causes thermal stress and cracking at tube holes. The boiler maker's start-up curve sets the allowed rate.

How much does a warm start save?

Starting at 90 °C instead of 30 °C saves the heat for that 60 K of water and steel: about 40 % of the cold-start heat in this example (5.8 GJ instead of 9.6 GJ).

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.