FireCADCalc

Boiler Rating Conversion (kg/h, kW, BHP, F&A)

Converts a boiler's steam output into heat output (kW, kcal/h, Btu/h), equivalent evaporation from and at 100 °C, and boiler horsepower.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerBoiler attendant and boiler operator examinations

Inputs

Examples: 10 t/h at 10.5 bar(a) saturated, feed 105 °C50 t/h at 66 bar(a) / 485 °C, feed 150 °C2 t/h at 8 bar(a) saturated, feed 30 °C

Results

Heat output38,107kW
Equivalent evaporation from and at 100 °C60,796kg/h
Boiler horsepower3,885.0
Factor of evaporation1.2159

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h at 10.5 bar(a) saturated, feed 105 °C. The inputs, in the units selected above:

InputValue
Steam output10,000 kg/h
Steam pressure (absolute)10.500 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Feedwater temperature105.00 °C

Applying the formula below gives:

ResultValue
Heat output6,494.6 kW
Equivalent evaporation from and at 100 °C10,362 kg/h
Boiler horsepower662.12
Factor of evaporation1.0362

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_s\,(h_s - h_{fw}) \qquad F = \frac{h_s - h_{fw}}{h_{fg,100}} \qquad \dot m_e = \frac{\dot Q}{h_{fg,100}}\)

\(BHP = \frac{\dot m_e}{34.5\ \text{lb/h}}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam output kg/s
\(p\) steam pressure, absolute Pa
\(\text{state}\) saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(T_{fw}\) feedwater temperature K
\(\dot Q\) heat output W
\(\dot m_e\) equivalent evaporation from and at 100 °C kg/s
\(BHP\) boiler horsepower –
\(F\) factor of evaporation –
\(h_s\) steam enthalpy J/kg
\(h_{fw}\) feedwater enthalpy J/kg
\(h_{fg,100}\) latent heat at 100 °C, computed from IF97 (about 2256.5 kJ/kg) J/kg

Method and standards

Heat output from IAPWS-IF97 enthalpies; equivalent evaporation from and at 100 °C with the IF97 latent heat at 100 °C; boiler horsepower as 34.5 lb/h of water evaporated from and at 212 °F (the ASME and ABMA definition).

Where it is used

  • Comparing quotations rated in t/h, kW, kcal/h, BHP or F&A.
  • Converting an imported (US) boiler rating to SI.
  • Checking boiler capacity against a heat load.

Common mistakes

  • Treating an F&A rating as the actual steam output: at 10 bar and 80 °C feed the real output is about 5–10 % less.
  • Confusing boiler horsepower with mechanical horsepower (745.7 W).
  • Using gauge pressure as absolute.

Assumptions and limits

  • Steam dry saturated or at the given superheat; no blowdown.

References

  • ASME definition of boiler horsepower (34.5 lb/h from and at 212 °F)
  • IAPWS R7-97(2012) IF97

Questions and answers

How do I convert boiler t/h to kW?

Multiply the steam flow by the heat added per kg. 10 t/h of saturated steam at 10.5 bar(a) from feedwater at 105 °C is 6.49 MW, equivalent to 10.36 t/h from and at 100 °C, or 662 boiler horsepower.

What is "from and at 100 °C"?

The steam a boiler would make if it received water at 100 °C and made saturated steam at 100 °C, so every kg takes 2257 kJ. It lets boilers working at different pressures and feed temperatures be compared; shell boiler makers often quote it.

What is a boiler horsepower?

An American unit: 34.5 lb/h of water evaporated from and at 212 °F, about 9.81 kW. It has nothing to do with mechanical horsepower.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.