FireCADCalc

Boiler Horsepower to Steam Output

Steam generation of a boiler from its boiler horsepower (33,475 Btu/h each), steam pressure, feedwater temperature and blowdown, by Ganapathy's energy balance.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Ganapathy: 500 BHP, 125 psig, 230 °F feed, 5 %200 BHP at 10 bar(a), 105 °C feed, 3 %

Results

One boiler horsepower is 33,475 Btu/h (9.81 kW), equal to 34.5 lb/h evaporated from and at 212 °F.

Heat output4,905.3kW
Steam generated7,582.1kg/h
Blowdown379.11kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 500 BHP, 125 psig, 230 °F feed, 5 %. The inputs, in the units selected above:

InputValue
Boiler horsepower500.00 -
Saturated steam pressure (absolute)9.6320 bar
Feedwater temperature110.00 °C
Blowdown as a share of steam5.0000 %

Applying the formula below gives:

ResultValue
Heat output4,905.3 kW
Steam generated7,582.1 kg/h
Blowdown379.11 kg/h

Open this example in the calculator and change any input.

Formula

\(W = \frac{BHP \times 33\,475\ \mathrm{Btu/h}}{(h_g - h_{fw}) + BD\,(h_f - h_{fw})}\)

Variables

Symbol Meaning SI unit
\(BHP\) Boiler horsepower -
\(p\) Saturated steam pressure (absolute) Pa
\(T_{fw}\) Feedwater temperature K
\(BD\) Blowdown as a share of steam -
\(Q\) Heat output W
\(W\) Steam generated kg/s
\(W_{BD}\) Blowdown kg/s
\(h_g, h_f, h_{fw}\) Enthalpies of saturated steam, saturated water and feedwater J/kg

Method and standards

Ganapathy's energy balance with IF97 enthalpies.

Where it is used

  • Rating package fire-tube boilers.
  • Comparing US and metric boiler data.

Common mistakes

  • Using kg/h 'from and at' as actual steam.
  • Ignoring blowdown.

Assumptions and limits

  • Saturated steam; heat losses within the rating.
  • Feedwater enthalpy is taken as saturated liquid at the feedwater temperature, not compressed liquid at boiler pressure; the difference is well under 0.5 % at shell-boiler pressures.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q1.08 (steam output of a boiler from its horsepower)
  • Steam and water enthalpies from IAPWS-IF97

Questions and answers

What is a boiler horsepower?

33,475 Btu/h, the heat to evaporate 34.5 lb/h of water from and at 212 °F.

Why does blowdown reduce the steam?

Blowdown leaves as hot saturated water that was heated but not evaporated.

Is the 500 BHP example in Ganapathy?

Yes: 500 BHP at 125 psig, 230 °F feed and 5 % blowdown gives about 16,700 lb/h.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.