UV Photolysis Reactor: Rate Constant and Treatable Flow

Photon flux per volume, first-order photolysis rate constant of a micropollutant and the flow a UV reactor treats for a target removal with tanks in series.

Inputs

Examples: Illustrative: 8 lamps of 10 kW at 15 %, 1.5 m3 as 5 tanks, eps 1650, Phi 0.3, k' 0.25/cm, 50 to 5 ng/LLow-absorbance water (k' 0.05/cm), 2 log

Accepted: 1 to 1,000
Accepted: 0.01 to 100 kW
Accepted: 1 to 60 %
Accepted: 200 to 400 nm
Accepted: 1 to 100,000 L
Accepted: 1 to 100,000
Accepted: 0.001 to 1
Accepted: 0.001 to 10 1/cm
Accepted: 1 to 50
Accepted: 0.001 to 1,000,000 ng/L
Accepted: 1E-4 to 1,000,000 ng/L

Results

Optically thick water (all UV absorbed by the water): k = Φ P_UV ε' / k', with ε' = 2.303ε. Wall and sleeve losses are not included; the removal follows n equal mixed tanks in series.

Photon flux per volume, einstein/(L·s)1.6986e-05
Photolysis rate constant0.0774421/s
Hydraulic residence time needed37.763s
Flow that can be treated39.721L/s
Electrical energy per order0.55946kWh/m³
Orders of removal1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 8 lamps of 10 kW at 15 %, 1.5 m3 as 5 tanks, eps 1650, Phi 0.3, k' 0.25/cm, 50 to 5 ng/L. The inputs, in the units selected above:

InputValue
Number of lamps8.0000 -
Electrical power per lamp10.000 kW
Lamp efficiency to UV at the working wavelength15.000 %
Wavelength254.00 nm
Reactor water volume1,500.0 L
Molar absorption coefficient of the target (decadic)1,650.0 -
Quantum yield, mol/einstein0.30000 -
Water absorption coefficient (natural-log basis)0.25000 1/cm
Equivalent tanks in series5.0000 -
Influent concentration0.050000 ng/L
Target effluent concentration0.005000 ng/L

Applying the formula below gives:

ResultValue
Photon flux per volume, einstein/(L·s)1.6986e-05
Photolysis rate constant0.077442 1/s
Hydraulic residence time needed37.763 s
Flow that can be treated39.721 L/s
Electrical energy per order0.55946 kWh/m³
Orders of removal1.0000

Open this example in the calculator and change any input.

Formula

\(P_{UV} = \frac{n_lP_l\eta_{UV}\lambda}{hcN_AV}, \quad k = \frac{\Phi P_{UV}\,2.303\,\varepsilon}{k'}\)

\(\tau = \frac{n}{k}\left[\left(\frac{C_0}{C_e}\right)^{1/n} - 1\right], \quad Q = \frac{V}{\tau}, \quad EE/O = \frac{n_lP_l}{Q\log(C_0/C_e)}\)

Variables

Symbol Meaning SI unit
\(n_l\) Number of lamps -
\(P_l\) Electrical power per lamp W
\(\eta_{UV}\) Lamp efficiency to UV at the working wavelength -
\(\lambda\) Wavelength m
\(V\) Reactor water volume m³
\(\varepsilon\) Molar absorption coefficient of the target (decadic) -
\(\Phi\) Quantum yield, mol/einstein -
\(k'\) Water absorption coefficient (natural-log basis) 1/m
\(n\) Equivalent tanks in series -
\(C_0\) Influent concentration kg/m³
\(C_e\) Target effluent concentration kg/m³
\(P_{UV}\) Photon flux per volume, einstein/(L·s) -
\(k\) Photolysis rate constant 1/s
\(\tau\) Hydraulic residence time needed s
\(Q\) Flow that can be treated m³/s
\(EE/O\) Electrical energy per order J/m³
\(\log(C_0/C_e)\) Orders of removal -

Method and standards

Direct photolysis kinetics with photon balance and tanks-in-series flow.

Where it is used

  • NDMA and other photolabile micropollutant removal.
  • Comparing UV reactor offers.

Common mistakes

  • Using the decadic ε where the natural-log ε' is needed.
  • Ignoring lamp efficiency (only 15–30 % of power is UV-C).

Assumptions and limits

  • Monochromatic light; no wall or sleeve losses; optically thick.

References

  • Photolysis rate in optically thick water k = Φ P_UV 2.303ε/k' with tanks-in-series hydraulics

Questions and answers

Why does the water's absorbance matter?

In optically thick water the water absorbs almost all the UV; the target's share is its absorbance divided by the water's, so a cleaner water speeds removal.

Why tanks in series?

A real reactor lies between plug flow and full mixing; the tracer-derived number of tanks sets how much residence time a given removal needs.

What do the defaults represent?

An illustrative reactor: 8 lamps of 10 kW at 15 % UV efficiency, 1.5 m³ of water behaving as 5 tanks, a target with ε 1650 L/(mol·cm) and Φ 0.3, water k' 0.25/cm, 50 to 5 ng/L.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 8-4, eqs. 8-115 to 8-126 and Example 8-13

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.