Electrical Energy per Order (EE/O) of a UV or AOP Reactor

Electrical energy per order of magnitude of contaminant destruction for a UV photolysis or advanced oxidation reactor from lamp power, flow and removal.

Inputs

Examples: UV/H2O2 for 1,4-dioxane: 60 kW, 50 L/s, 3 to 0.3 ug/LTaste and odour (MIB) 2-log at 400 kW, 1 m3/s

Accepted: 0.001 to 10,000 kW
Accepted: 0.01 to 100,000 L/s
Accepted: 1E-12 to 1E+12
Accepted: 1E-12 to 1E+12

Results

EE/O (Bolton et al.) applies to dilute, first-order destruction where the energy for each order is constant. Typical UV/H₂O₂ values are 0.05–0.5 kWh/m³ per order.

Orders of magnitude removed1.0000
Electrical energy per volume treated0.33333kWh/m³
Electrical energy per order0.33333kWh/m³
EE/O per 1,000 US gallons, kWh1.2618

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: UV/H2O2 for 1,4-dioxane: 60 kW, 50 L/s, 3 to 0.3 ug/L. The inputs, in the units selected above:

InputValue
Lamp electrical power60.000 kW
Flow50.000 L/s
Influent concentration (any unit)3.0000 -
Effluent concentration (same unit)0.30000 -

Applying the formula below gives:

ResultValue
Orders of magnitude removed1.0000
Electrical energy per volume treated0.33333 kWh/m³
Electrical energy per order0.33333 kWh/m³
EE/O per 1,000 US gallons, kWh1.2618

Open this example in the calculator and change any input.

Formula

\(EE/O = \frac{P}{Q\log_{10}(C_i/C_f)}\)

Variables

Symbol Meaning SI unit
\(P\) Lamp electrical power W
\(Q\) Flow m³/s
\(C_i\) Influent concentration (any unit) -
\(C_f\) Effluent concentration (same unit) -
\(\log(C_i/C_f)\) Orders of magnitude removed -
\(E/V\) Electrical energy per volume treated J/m³
\(EE/O\) Electrical energy per order J/m³
\(EE/O_{US}\) EE/O per 1,000 US gallons, kWh -

Method and standards

Electrical energy per order figure of merit (Bolton et al., 2001).

Where it is used

  • Comparing UV and AOP vendor offers.
  • Operating cost estimates for micropollutant destruction.

Common mistakes

  • Using lamp UV output instead of electrical input.
  • Applying EE/O at high concentrations where kinetics are not first order.

Assumptions and limits

  • First-order destruction; electrical energy only.

Questions and answers

Why per order?

For first-order destruction each tenfold reduction costs the same energy, so EE/O compares reactors and waters fairly.

What raises EE/O?

UV absorbance of the water (low UVT), radical scavengers such as bicarbonate and NOM, and lamp ageing.

What do the defaults represent?

An illustrative case: UV/H2O2 for 1,4-dioxane: 60 kW, 50 L/s, 3 to 0.3 ug/L. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crittenden et al., MWH's Water Treatment: Principles and Design, 3rd ed. (Wiley, 2012), sec. 8-6 and 18-5, Example 8-14 (Bolton et al., 2001)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.