Worked example
Example: Illustrative 300 mm sewer, 1 mm grit. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pipe diameter (running full or half full) | 300.00 mm |
| Manning roughness | 0.013000 - |
| Dimensionless constant (0.04 start of motion to 0.8 scour) | 0.060000 - |
| Specific gravity of the particle | 2.6500 - |
| Particle diameter | 1.0000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic radius D/4 | 75.000 mm |
| Self-cleansing velocity | 0.49703 m/s |
| Minimum slope | 0.001320 |
| Full-bore flow at that slope | 35.133 L/s |
Open this example in the calculator and change any input.
Formula
\(S = \frac{k(G_s - 1)d}{R}, \quad V_s = \frac1nR^{1/6}\sqrt{k(G_s - 1)d}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Pipe diameter (running full or half full) | m |
| \(n\) | Manning roughness | - |
| \(k\) | Dimensionless constant (0.04 start of motion to 0.8 scour) | - |
| \(G_s\) | Specific gravity of the particle | - |
| \(d\) | Particle diameter | m |
| \(R\) | Hydraulic radius D/4 | m |
| \(V_s\) | Self-cleansing velocity | m/s |
| \(S_{min}\) | Minimum slope | - |
| \(Q\) | Full-bore flow at that slope | m³/s |
Method and standards
Self-cleansing.
Where it is used
- Sewer gradient design.
- Checking flat sewers for deposits.
Common mistakes
- Using velocity alone for very large sewers (shear stress governs).
- Taking k for clean grit where fats and rags bind deposits.
Assumptions and limits
- Uniform flow; circular pipe full or half full; non-cohesive particle.
References
- Camp's self-cleansing velocity
Questions and answers
Why is the velocity the same full and half full?
A circular pipe has R = D/4 in both states, so slope and velocity are the same.
What k should I use?
About 0.04–0.06 for clean grit; up to 0.8 to scour deposits that have consolidated.
What do the defaults represent?
An illustrative 300 mm concrete sewer (n = 0.013) moving 1 mm grit of G_s = 2.65 with k = 0.06.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Camp, Sedimentation and the Design of Settling Tanks, Trans. ASCE 111 (1946); Metcalf and Eddy, Wastewater Engineering, 5th ed. (McGraw-Hill, 2014)