FireCADCalc

Partly Full Circular Pipe: Area, Hydraulic Radius and Manning Flow

Flow area, wetted perimeter, hydraulic radius, Manning velocity and discharge of a circular pipe flowing partly full, with the ratios to the full-pipe values.

Inputs

Examples: Illustrative: 600 mm sewer, n 0.013, slope 0.4 %, 360 mm deepHalf full 300 mm drain, 1 %Large 1500 mm culvert running 1.4 m deep, 0.2 %

Accepted: 10 to 10,000 mm
Accepted: 0.1 to 10,000 mm
Accepted: 1E-4 to 50 %
Accepted: 0.008 to 0.05

Results

Manning's equation with the circular-segment geometry, constant n. The maximum discharge occurs at about 0.94D and the maximum velocity at about 0.81D, both slightly above full-pipe values.

Central angle subtended by the water surface300.15°
Flow area1.7166m²
Wetted perimeter3.9289m
Hydraulic radius436.90mm
Velocity1.7166m/s
Discharge2,946.7L/s
Discharge relative to full107.55%
Velocity relative to full110.72%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 600 mm sewer, n 0.013, slope 0.4 %, 360 mm deep. The inputs, in the units selected above:

InputValue
Pipe internal diameter600.00 mm
Flow depth360.00 mm
Pipe slope0.40000 %
Manning roughness0.013000 -

Applying the formula below gives:

ResultValue
Central angle subtended by the water surface203.07 °
Flow area0.17713 m²
Wetted perimeter1.0633 m
Hydraulic radius166.59 mm
Velocity1.4729 m/s
Discharge260.90 L/s
Discharge relative to full67.184 %
Velocity relative to full107.24 %

Open this example in the calculator and change any input.

Formula

\(\theta = 2\cos^{-1}\left(1 - \frac{2y}{D}\right), \quad A = \frac{D^2}{8}(\theta - \sin\theta), \quad P = \frac{D\theta}{2}, \quad V = \frac{1}{n}R^{2/3}S^{1/2}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe internal diameter m
\(y\) Flow depth m
\(S\) Pipe slope -
\(n\) Manning roughness -
\(\theta\) Central angle subtended by the water surface rad
\(A\) Flow area m²
\(P\) Wetted perimeter m
\(R\) Hydraulic radius m
\(V\) Velocity m/s
\(Q\) Discharge m³/s
\(Q/Q_{full}\) Discharge relative to full -
\(V/V_{full}\) Velocity relative to full -

Method and standards

Circular-segment geometry with Manning's equation.

Where it is used

  • Sewer and storm drain design and checks.
  • Culverts flowing part full.

Common mistakes

  • Using the full-pipe hydraulic radius D/4 at part depth.
  • Expecting exactly full-pipe capacity at y = D.

Assumptions and limits

  • Uniform flow, constant Manning n.

References

  • Manning's equation for a part-full circular section

Questions and answers

Why can a pipe carry more just below full?

Near the crown the wetted perimeter grows faster than the area, so the hydraulic radius and the discharge peak at about 94 % depth.

What depth should sewers be designed for?

Many authorities size sewers to run at 50–80 % of the diameter at peak flow, keeping space for air and surcharge.

What do the defaults represent?

An illustrative 600 mm concrete sewer (n 0.013) on a 0.4 % slope flowing 360 mm deep.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chow, Open-Channel Hydraulics (McGraw-Hill, 1959), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.