Muskingum Flood Routing Coefficients and Outflow

Muskingum routing coefficients C₀, C₁, C₂ from the storage constant, weighting factor and time step, with the outflow at the end of one step of a river reach.

Inputs

Examples: Illustrative: K 12 h, X 0.2, dt 6 h, inflow 120 to 260, outflow 100 m3/sRecession: K 8 h, X 0.1, dt 4 h, inflow 400 to 300, outflow 420

Accepted: 0.016667 to 2,777.8 h
Accepted: 0 to 0.5
Accepted: 0.016667 to 2,777.8 h
Accepted: 0 to 1,000,000 m³/s
Accepted: 0 to 1,000,000 m³/s
Accepted: 0 to 1,000,000 m³/s

Results

Muskingum storage S = K[XI + (1 − X)O] with the continuity equation over the step; C₀ + C₁ + C₂ = 1.

Coefficient on I₂0.13043
Coefficient on I₁0.30435
Coefficient on O₁0.56522
Outflow at the end of the step398.26m³/s
Change in reach storage over the step-851,478m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: K 12 h, X 0.2, dt 6 h, inflow 120 to 260, outflow 100 m3/s. The inputs, in the units selected above:

InputValue
Storage (travel time) constant12.000 h
Weighting factor (0 to 0.5)0.20000 -
Routing time step6.0000 h
Inflow at the start of the step120.00 m³/s
Inflow at the end of the step260.00 m³/s
Outflow at the start of the step100.00 m³/s

Applying the formula below gives:

ResultValue
Coefficient on I₂0.047619
Coefficient on I₁0.42857
Coefficient on O₁0.52381
Outflow at the end of the step116.19 m³/s
Change in reach storage over the step1,769,143 m³

Open this example in the calculator and change any input.

Formula

\(C_0 = \frac{\Delta t - 2KX}{2K(1 - X) + \Delta t}, \quad C_1 = \frac{\Delta t + 2KX}{2K(1 - X) + \Delta t}, \quad C_2 = \frac{2K(1 - X) - \Delta t}{2K(1 - X) + \Delta t}\)

\(O_2 = C_0I_2 + C_1I_1 + C_2O_1\)

Variables

Symbol Meaning SI unit
\(K\) Storage (travel time) constant s
\(X\) Weighting factor (0 to 0.5) -
\(\Delta t\) Routing time step s
\(I_1\) Inflow at the start of the step m³/s
\(I_2\) Inflow at the end of the step m³/s
\(O_1\) Outflow at the start of the step m³/s
\(C_0\) Coefficient on I₂ -
\(C_1\) Coefficient on I₁ -
\(C_2\) Coefficient on O₁ -
\(O_2\) Outflow at the end of the step m³/s
\(\Delta S\) Change in reach storage over the step m³

Method and standards

Muskingum linear storage routing.

Where it is used

  • Flood forecasting along rivers.
  • Design of channel reaches and detention.

Common mistakes

  • Choosing a time step outside 2KX to 2K(1 − X).
  • Using X above 0.5.

Assumptions and limits

  • Linear storage, no lateral inflow.

References

  • Muskingum hydrologic routing

Questions and answers

How are K and X found?

From observed inflow and outflow hydrographs of the reach: plot storage against XI + (1 − X)O for trial X until the loop collapses to a line of slope K. K is close to the travel time through the reach.

How do I route a whole hydrograph?

Apply O₂ = C₀I₂ + C₁I₁ + C₂O₁ step by step, using each step's outflow as the next O₁.

What do the defaults represent?

An illustrative reach with K = 12 h and X = 0.2 routed in 6-hour steps as the inflow rises from 120 to 260 m³/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), sec. 8.4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.