FireCADCalc

Green–Ampt Infiltration and Ponding Time

Cumulative infiltration and infiltration rate by the Green–Ampt model, with the ponding time under steady rain, from conductivity, suction head and moisture deficit.

Inputs

Examples: Illustrative loam: K 6.5 mm/h, psi 110 mm, deficit 0.30, ponded, 1 hSandy loam under 30 mm/h rain for 2 hLight rain below K (no ponding)

Accepted: 0.00036 to 3,600 mm/h
Accepted: 1 to 2,000 mm
Accepted: 0.1 to 60 %
Accepted: 0.00027778 to 2,777.8 h
Accepted: 0 to 3,600 mm/h

Results

The rain never exceeds the saturated conductivity: everything infiltrates and no ponding occurs.

Cumulative infiltration10.000mm
Infiltration rate5.0000mm/h
Ponding time (0 if ponded from the start)0h
Infiltration at ponding0mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative loam: K 6.5 mm/h, psi 110 mm, deficit 0.30, ponded, 1 h. The inputs, in the units selected above:

InputValue
Saturated hydraulic conductivity6.5000 mm/h
Wetting front suction head110.00 mm
Moisture deficit (porosity minus initial content)30.000 %
Time1.0000 h
Rainfall intensity (0 for ponded from the start)0 mm/h

Applying the formula below gives:

ResultValue
Cumulative infiltration25.254 mm
Infiltration rate14.994 mm/h
Ponding time (0 if ponded from the start)0 h
Infiltration at ponding0 mm

Open this example in the calculator and change any input.

Formula

\(F - \psi\Delta\theta\ln\left(1 + \frac{F}{\psi\Delta\theta}\right) = Kt, \quad f = K\left(1 + \frac{\psi\Delta\theta}{F}\right), \quad t_p = \frac{K\psi\Delta\theta}{i(i - K)}\)

Variables

Symbol Meaning SI unit
\(K\) Saturated hydraulic conductivity m/s
\(\psi\) Wetting front suction head m
\(\Delta\theta\) Moisture deficit (porosity minus initial content) -
\(t\) Time s
\(i\) Rainfall intensity (0 for ponded from the start) m/s
\(F\) Cumulative infiltration m
\(f\) Infiltration rate m/s
\(t_p\) Ponding time (0 if ponded from the start) s
\(F_p\) Infiltration at ponding m

Method and standards

Physically based infiltration model.

Where it is used

  • Runoff and flood modelling, drainage design.
  • Irrigation and soil water studies.

Common mistakes

  • Using the total porosity instead of the moisture deficit.
  • Ignoring ponding time under light rain.

Assumptions and limits

  • Homogeneous soil, sharp wetting front, ponded water depth negligible.

References

  • Green–Ampt infiltration with the Mein–Larson ponding time

Questions and answers

Where do the soil parameters come from?

Rawls and Brakensiek tabulated K, ψ and porosity by soil texture; for a silt loam K ≈ 6.5 mm/h and ψ ≈ 170 mm, for a sandy loam K ≈ 11 mm/h and ψ ≈ 110 mm.

What is the ponding time?

Under steady rain heavier than K, the time when the soil can no longer absorb all the rain and water starts to pond and run off.

What do the defaults represent?

An illustrative loam (K 6.5 mm/h, suction 110 mm, moisture deficit 0.30) ponded from the start, after one hour.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chow, Maidment and Mays, Applied Hydrology (McGraw-Hill, 1988), sec. 4.3 and 4.4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.