FireCADCalc

Flashing Flow of Saturated Water (Homogeneous Equilibrium Model)

Critical (choked) mass flux and flow of saturated water flashing through an orifice or blowdown valve by the homogeneous equilibrium model (isentropic, IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 46 bar blowdown to atmosphere11 bar drain

Results

HEM assumes thermal and mechanical equilibrium; short orifices pass more than HEM predicts because flashing lags. A conservative low estimate for long valves and pipes.

Throat pressure at maximum flux9.7543bar
Mass flux6,930.4kg/(m²·s)
Mass flow3.3067t/h
Steam quality at the throat1.1396%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 46 bar blowdown to atmosphere. The inputs, in the units selected above:

InputValue
Upstream pressure, saturated water (absolute)46.000 bar
Back pressure (absolute)1.0132 bar
Orifice or valve throat diameter20.000 mm
Discharge coefficient0.80000 -

Applying the formula below gives:

ResultValue
Throat pressure at maximum flux37.491 bar
Mass flux19,844 kg/(m²·s)
Mass flow17.955 t/h
Steam quality at the throat3.3521 %

Open this example in the calculator and change any input.

Formula

\(G = \max_p \frac{\sqrt{2[h_0 - h(p, s_0)]}}{v(p, s_0)}, \quad \dot m = C_d G \frac{\pi d^2}{4}\)

Variables

Symbol Meaning SI unit
\(p_0\) Upstream pressure, saturated water (absolute) Pa
\(p_b\) Back pressure (absolute) Pa
\(d\) Orifice or valve throat diameter m
\(C_d\) Discharge coefficient -
\(p_c\) Throat pressure at maximum flux Pa
\(G\) Mass flux kg/(m²·s)
\(\dot m\) Mass flow kg/s
\(x_c\) Steam quality at the throat -

Method and standards

Homogeneous equilibrium model: the saturated water expands isentropically and the mass flux is maximised over the throat pressure between the back pressure and the upstream pressure (coarse scan, then golden-section search). If the maximum would lie below the back pressure the flow is not choked and the throat is at the back pressure.

Where it is used

  • Blowdown valve sizing.
  • Leak and drain flows.

Common mistakes

  • Using incompressible water flow.

Assumptions and limits

  • Saturated water upstream; equilibrium flashing. Subcooled water (for example downstream of a cooler) cannot be entered; it flows more.
  • Upstream velocity neglected.

References

  • Homogeneous equilibrium model: G = max √(2(h₀ − h(p, s₀)))/v(p, s₀) along the isentrope (Collier and Thome, Convective Boiling and Condensation, 3rd ed., Oxford, 1994); properties from IAPWS-IF97

Questions and answers

Why does flashing flow choke?

As pressure falls the mixture expands so fast that mass flux reaches a maximum at the throat.

HEM or frozen models?

HEM is conservative (low) for long valves and pipes; short orifices pass more.

Use?

Blowdown valve and drain sizing, and leak flow from a hole in a pressurised water line.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.