Worked example
Example: Travelling grate 10 t/h coal, 35 % excess air, 25 % OFA. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel firing rate | 10.000 t/h |
| Stoichiometric air per kg fuel | 5.5000 kg/kg |
| Excess air | 35.000 % |
| Overfire air share of the total air | 25.000 % |
| Zone 1 (front) share of the undergrate air | 15.000 % |
| Zone 2 share | 35.000 % |
| Zone 3 share | 35.000 % |
| Zone 4 (rear) share | 15.000 % |
| Active grate area | 25.000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total combustion air | 74.250 t/h |
| Overfire air | 18.562 t/h |
| Undergrate air | 55.688 t/h |
| Air to zone 1 | 8.3531 t/h |
| Air to zone 2 | 19.491 t/h |
| Air to zone 3 | 19.491 t/h |
| Air to zone 4 | 8.3531 t/h |
| Undergrate air per m² of grate | 0.61875 kg/(m²·s) |
Open this example in the calculator and change any input.
Formula
\(\dot m_a = \dot m_f\, a_{st} (1 + EA)\)
\(\dot m_{OFA} = f_{OFA} \dot m_a, \quad \dot m_{UGA} = (1 - f_{OFA}) \dot m_a\)
\(\dot m_i = z_i \dot m_{UGA}, \quad G_{UGA} = \dot m_{UGA} / A_g\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_f\) | fuel firing rate | kg/s |
| \(a_{st}\) | stoichiometric air per kg fuel | kg/kg |
| \(EA\) | excess air | - |
| \(f_{OFA}\) | overfire air share | - |
| \(z_1\) | zone 1 share of undergrate air | - |
| \(z_2\) | zone 2 share | - |
| \(z_3\) | zone 3 share | - |
| \(z_4\) | zone 4 share | - |
| \(z_i\) | share of zone i | - |
| \(A_g\) | active grate area | m² |
| \(\dot m_a\) | total combustion air | kg/s |
| \(\dot m_{OFA}\) | overfire air | kg/s |
| \(\dot m_{UGA}\) | undergrate air | kg/s |
| \(\dot m_1\) | air to zone 1 | kg/s |
| \(\dot m_2\) | air to zone 2 | kg/s |
| \(\dot m_3\) | air to zone 3 | kg/s |
| \(\dot m_4\) | air to zone 4 | kg/s |
| \(\dot m_i\) | air to zone i | kg/s |
| \(G_{UGA}\) | undergrate air per m² of grate | kg/(m²·s) |
Method and standards
Total air is the stoichiometric air for the fuel times one plus the excess air. The overfire share is taken off the top; the rest is split between the grate zones by the chosen shares, which must add up to 100 %.
Where it is used
- Setting zone dampers on a travelling, chain or dumping grate.
- Sizing the overfire air fan.
- Checking grate loading.
Common mistakes
- Zone shares not adding up to 100 %.
- Using the total grate area including dead plates.
- Counting fuel-feeder or spreader air twice.
Assumptions and limits
- Air leakage through grate seals not included.
- Stoichiometric air from the combustion calculator for the fuel, as dry air per kg of fuel as fired; the flows are dry air.
- A note appears when the overfire share is outside 20–35 %. The undergrate air per m² is not checked against a limit; the grate maker gives the range for the fuel.
- Four zones; merge or split shares for other grates.
References
- Combustion air mass balance
Questions and answers
How is grate air usually split?
Most air goes under the grate where the fuel burns hardest (the middle zones), less at the front (drying) and rear (burnout); 20–35 % is overfire air above the grate.
Why use overfire air?
Volatiles released from the fuel bed burn above it; overfire air mixes and burns them, lowering CO and unburnt losses.
What does undergrate air per m² tell me?
How hard the grate is being pushed; too high lifts fine fuel off the grate and raises carry-over.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.