Grate Boiler Air Split: Undergrate Zones and Overfire Air

Total combustion air of a grate-fired boiler, the overfire air, the undergrate air to each of four grate zones and the undergrate air per m² of grate.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerBurner and furnaceFan and blower

Inputs

Examples: Travelling grate 10 t/h coal, 35 % excess air, 25 % OFABagasse 30 t/h on a dumping grate, 40 %, 30 % OFAChain grate 6 t/h, 50 %, 20 % OFA

Dry air per kg of fuel as fired, from the combustion calculator for the fuel analysis. The results are then dry air; add the air humidity for wet air flows.

Results

Total combustion air134.40t/h
Overfire air40.320t/h
Undergrate air94.080t/h
Air to zone 118.816t/h
Air to zone 228.224t/h
Air to zone 328.224t/h
Air to zone 418.816t/h
Undergrate air per m² of grate0.43556kg/(m²·s)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Travelling grate 10 t/h coal, 35 % excess air, 25 % OFA. The inputs, in the units selected above:

InputValue
Fuel firing rate10.000 t/h
Stoichiometric air per kg fuel5.5000 kg/kg
Excess air35.000 %
Overfire air share of the total air25.000 %
Zone 1 (front) share of the undergrate air15.000 %
Zone 2 share35.000 %
Zone 3 share35.000 %
Zone 4 (rear) share15.000 %
Active grate area25.000 m²

Applying the formula below gives:

ResultValue
Total combustion air74.250 t/h
Overfire air18.562 t/h
Undergrate air55.688 t/h
Air to zone 18.3531 t/h
Air to zone 219.491 t/h
Air to zone 319.491 t/h
Air to zone 48.3531 t/h
Undergrate air per m² of grate0.61875 kg/(m²·s)

Open this example in the calculator and change any input.

Formula

\(\dot m_a = \dot m_f\, a_{st} (1 + EA)\)

\(\dot m_{OFA} = f_{OFA} \dot m_a, \quad \dot m_{UGA} = (1 - f_{OFA}) \dot m_a\)

\(\dot m_i = z_i \dot m_{UGA}, \quad G_{UGA} = \dot m_{UGA} / A_g\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) fuel firing rate kg/s
\(a_{st}\) stoichiometric air per kg fuel kg/kg
\(EA\) excess air -
\(f_{OFA}\) overfire air share -
\(z_1\) zone 1 share of undergrate air -
\(z_2\) zone 2 share -
\(z_3\) zone 3 share -
\(z_4\) zone 4 share -
\(z_i\) share of zone i -
\(A_g\) active grate area m²
\(\dot m_a\) total combustion air kg/s
\(\dot m_{OFA}\) overfire air kg/s
\(\dot m_{UGA}\) undergrate air kg/s
\(\dot m_1\) air to zone 1 kg/s
\(\dot m_2\) air to zone 2 kg/s
\(\dot m_3\) air to zone 3 kg/s
\(\dot m_4\) air to zone 4 kg/s
\(\dot m_i\) air to zone i kg/s
\(G_{UGA}\) undergrate air per m² of grate kg/(m²·s)

Method and standards

Total air is the stoichiometric air for the fuel times one plus the excess air. The overfire share is taken off the top; the rest is split between the grate zones by the chosen shares, which must add up to 100 %.

Where it is used

  • Setting zone dampers on a travelling, chain or dumping grate.
  • Sizing the overfire air fan.
  • Checking grate loading.

Common mistakes

  • Zone shares not adding up to 100 %.
  • Using the total grate area including dead plates.
  • Counting fuel-feeder or spreader air twice.

Assumptions and limits

  • Air leakage through grate seals not included.
  • Stoichiometric air from the combustion calculator for the fuel, as dry air per kg of fuel as fired; the flows are dry air.
  • A note appears when the overfire share is outside 20–35 %. The undergrate air per m² is not checked against a limit; the grate maker gives the range for the fuel.
  • Four zones; merge or split shares for other grates.

References

  • Combustion air mass balance

Questions and answers

How is grate air usually split?

Most air goes under the grate where the fuel burns hardest (the middle zones), less at the front (drying) and rear (burnout); 20–35 % is overfire air above the grate.

Why use overfire air?

Volatiles released from the fuel bed burn above it; overfire air mixes and burns them, lowering CO and unburnt losses.

What does undergrate air per m² tell me?

How hard the grate is being pushed; too high lifts fine fuel off the grate and raises carry-over.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.