FireCADCalc

LPG Vaporiser Duty and Heater Power

Heat needed to vaporise and superheat liquid LPG for a burner, and the vaporiser heater power, from the LPG flow, temperatures and the supplier's property data.

Process steam and utilitiesChemical and fertiliserPulp and paperFood, dairy and textileFuel oil and gas systemBurner and furnace

Inputs

Examples: 200 kg/h LPG, liquid 10 °C, vaporised at 30 °C, out 40 °C50 kg/h, 15 °C, 25 °C, 35 °C1000 kg/h, 5 °C, 35 °C, 45 °C

The boiling temperature of your LPG mix at the vaporiser pressure, from the supplier; enter the latent heat at this temperature.

LPG properties (illustrative defaults: use your supplier's data)

Results

Vaporiser duty5.7222kW
Heater power (electric or water bath)6.7320kW
Of which latent heat5.1389kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 200 kg/h LPG, liquid 10 °C, vaporised at 30 °C, out 40 °C. The inputs, in the units selected above:

InputValue
LPG flow200.00 kg/h
Liquid LPG temperature in10.000 °C
Vaporising temperature (at vaporiser pressure)30.000 °C
Vapour temperature out40.000 °C
Specific heat of the liquid2.5000 kJ/(kg·K)
Latent heat at the vaporising temperature380.00 kJ/kg
Specific heat of the vapour1.7000 kJ/(kg·K)
Vaporiser heater efficiency90.000 %

Applying the formula below gives:

ResultValue
Vaporiser duty24.833 kW
Heater power (electric or water bath)27.593 kW
Of which latent heat21.111 kW

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m\left[c_{p,l}\,(T_v - T_1) + h_{fg} + c_{p,v}\,(T_2 - T_v)\right] \qquad P = \frac{\dot Q}{\eta} \qquad \dot Q_l = \dot m\,h_{fg}\)

Variables

Symbol Meaning SI unit
\(\dot m\) LPG flow kg/s
\(T_1\) liquid temperature in K
\(T_v\) vaporising temperature K
\(T_2\) vapour temperature out K
\(c_{p,l}\) liquid specific heat J/(kg·K)
\(h_{fg}\) latent heat J/kg
\(c_{p,v}\) vapour specific heat J/(kg·K)
\(\eta\) heater efficiency –
\(\dot Q\) vaporiser duty W
\(P\) heater power W
\(\dot Q_l\) latent heat part W

Method and standards

Energy balance of the LPG through the vaporiser; properties are entered from the supplier's data.

Where it is used

  • Sizing electric and water-bath LPG vaporisers.
  • Checking whether vapour withdrawal from the tank is enough.
  • LPG-fired boilers, dryers and furnaces.

Common mistakes

  • Using pure propane data for a butane-rich mix.
  • Forgetting cold-weather sizing.
  • Ignoring the heater efficiency of water-bath units.

Assumptions and limits

  • Constant properties; single vaporising temperature (a propane–butane mix boils over a small temperature glide).
  • The vaporising temperature and latent heat must belong to the same vaporiser pressure; the defaults are illustrative, not supplier data.
  • Liquid entering above the vaporising temperature flashes; a warning is shown.

References

  • First law of thermodynamics (sensible plus latent heat)

Questions and answers

How big a vaporiser does LPG need?

Sensible heat to the boiling point, latent heat, then superheat. 200 kg/h of LPG from 10 °C, vaporised at 30 °C and leaving at 40 °C, needs 24.8 kW, 21.1 kW of it latent; a 90 % efficient heater needs 27.6 kW.

Where do I get the latent heat?

From the LPG supplier for your propane–butane mix and vaporiser pressure. The defaults here are only illustrative.

When is a vaporiser needed?

When the cylinders or tank cannot boil off enough vapour by themselves, especially in cold weather or at high draw rates.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.