Worked example
Example: 200 kg/h LPG, liquid 10 °C, vaporised at 30 °C, out 40 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| LPG flow | 200.00 kg/h |
| Liquid LPG temperature in | 10.000 °C |
| Vaporising temperature (at vaporiser pressure) | 30.000 °C |
| Vapour temperature out | 40.000 °C |
| Specific heat of the liquid | 2.5000 kJ/(kg·K) |
| Latent heat at the vaporising temperature | 380.00 kJ/kg |
| Specific heat of the vapour | 1.7000 kJ/(kg·K) |
| Vaporiser heater efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vaporiser duty | 24.833 kW |
| Heater power (electric or water bath) | 27.593 kW |
| Of which latent heat | 21.111 kW |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m\left[c_{p,l}\,(T_v - T_1) + h_{fg} + c_{p,v}\,(T_2 - T_v)\right] \qquad P = \frac{\dot Q}{\eta} \qquad \dot Q_l = \dot m\,h_{fg}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | LPG flow | kg/s |
| \(T_1\) | liquid temperature in | K |
| \(T_v\) | vaporising temperature | K |
| \(T_2\) | vapour temperature out | K |
| \(c_{p,l}\) | liquid specific heat | J/(kg·K) |
| \(h_{fg}\) | latent heat | J/kg |
| \(c_{p,v}\) | vapour specific heat | J/(kg·K) |
| \(\eta\) | heater efficiency | – |
| \(\dot Q\) | vaporiser duty | W |
| \(P\) | heater power | W |
| \(\dot Q_l\) | latent heat part | W |
Method and standards
Energy balance of the LPG through the vaporiser; properties are entered from the supplier's data.
Where it is used
- Sizing electric and water-bath LPG vaporisers.
- Checking whether vapour withdrawal from the tank is enough.
- LPG-fired boilers, dryers and furnaces.
Common mistakes
- Using pure propane data for a butane-rich mix.
- Forgetting cold-weather sizing.
- Ignoring the heater efficiency of water-bath units.
Assumptions and limits
- Constant properties; single vaporising temperature (a propane–butane mix boils over a small temperature glide).
- The vaporising temperature and latent heat must belong to the same vaporiser pressure; the defaults are illustrative, not supplier data.
- Liquid entering above the vaporising temperature flashes; a warning is shown.
References
- First law of thermodynamics (sensible plus latent heat)
Questions and answers
How big a vaporiser does LPG need?
Sensible heat to the boiling point, latent heat, then superheat. 200 kg/h of LPG from 10 °C, vaporised at 30 °C and leaving at 40 °C, needs 24.8 kW, 21.1 kW of it latent; a 90 % efficient heater needs 27.6 kW.
Where do I get the latent heat?
From the LPG supplier for your propane–butane mix and vaporiser pressure. The defaults here are only illustrative.
When is a vaporiser needed?
When the cylinders or tank cannot boil off enough vapour by themselves, especially in cold weather or at high draw rates.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.