Junkers Gas Calorimeter Calorific Value

Gross and net calorific value of a fuel gas from a Junkers (Boys) gas calorimeter: gas burnt, cooling water and its temperature rise, condensate, and gas volume corrected to normal conditions.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalPulp and paperIAPWS-IF97 (water and steam)Fuel oil and gas systemBurner and furnaceBoiler attendant and boiler operator examinations

Inputs

Examples: 10 L natural gas at 15 °C, 6 kg water 15 to 30 °C, 16 g condensate5 L LPG at 20 °C, 7 kg water 18 to 34.5 °C, 11 g20 L producer gas at 25 °C, 3 kg 20 to 28 °C, 4 gSame natural gas through a wet meter (saturated at 15 °C)

Results

Dry meter: the meter volume is taken as dry gas. For a wet (water-sealed) meter choose it above; the vapour lowers the dry volume by about 1.7 % at 15 °C.

Heat taken up by the water100.48kJ
Gas burnt at 0 °C and 101.325 kPa18.323L
Gross calorific value per m³ at meter conditions5,024.2kJ/m³
Gross calorific value per Nm³5,484.0kJ/Nm³
Net calorific value per Nm³4,951.0kJ/Nm³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 L natural gas at 15 °C, 6 kg water 15 to 30 °C, 16 g condensate. The inputs, in the units selected above:

InputValue
Gas burnt, by the meter10.000 L
Gas pressure at the meter (absolute)1,023.2 mbar
Gas temperature at the meter15.000 °C
Cooling water collected6.0000 kg
Water inlet temperature15.000 °C
Water outlet temperature30.000 °C
Specific heat of water4.1868 kJ/(kg·K)
Gas meterDry meter (dry gas)
Steam condensate collected (for the net value)16.000 g

Applying the formula below gives:

ResultValue
Heat taken up by the water376.81 kJ
Gas burnt at 0 °C and 101.325 kPa9.5730 L
Gross calorific value per m³ at meter conditions37,681 kJ/m³
Gross calorific value per Nm³39,362 kJ/Nm³
Net calorific value per Nm³35,281 kJ/Nm³

Open this example in the calculator and change any input.

Formula

\(Q = m_w\, c_w\, (T_{out} - T_{in})\)

\(V_N = V_g\, \frac{p_g - p_v}{101.325\ \text{kPa}}\, \frac{273.15\ \text{K}}{T_g}\)

\(GCV = \frac{Q}{V_N}, \quad NCV = GCV - \frac{m_c}{V_N}\, h_{fg,25}\)

Variables

Symbol Meaning SI unit
\(V_g\) Gas burnt, by the meter m³
\(p_g\) Gas pressure at the meter (absolute) Pa
\(T_g\) Gas temperature at the meter K
\(m_w\) Cooling water collected kg
\(T_{in}\) Water inlet temperature K
\(T_{out}\) Water outlet temperature K
\(c_w\) Specific heat of water J/(kg·K)
\(\text{meter}\) Gas meter: dry, or wet (water-sealed, gas saturated) -
\(p_v\) Water vapour pressure at T_g (IF97) for a wet meter; zero for a dry meter Pa
\(m_c\) Steam condensate collected (for the net value) kg
\(Q\) Heat taken up by the water J
\(V_N\) Gas burnt at 0 °C and 101.325 kPa m³
\(GCV_m\) Gross calorific value per m³ at meter conditions J/m³
\(GCV\) Gross calorific value per Nm³ J/m³
\(NCV\) Net calorific value per Nm³ J/m³

Method and standards

Heat from the burnt gas equals the heat taken up by the cooling water; the gas volume is corrected to 0 °C and 101.325 kPa by the ideal gas law.

Worked example

10 L of gas at 15 °C and 1023 mbar is burnt; 6 kg of water warms from 15 °C to 30 °C; 16 g of condensate is collected.

  • Q = 6 × 4.1868 × 15 = 376.8 kJ
  • V_N = 10 × 1023.25/1013.25 × 273.15/288.15 = 9.573 L
  • GCV = 376.8 / 0.009573 = 39 360 kJ/Nm³ = 39.4 MJ/Nm³
  • NCV = 39 360 − 0.016/0.009573 × 2442 = 35 280 kJ/Nm³

Where it is used

  • Boiler attendant and operator examinations.
  • Testing producer, biogas or LPG supplies.
  • Checking a gas supplier's calorific value.

Common mistakes

  • Using the meter volume without correction.
  • Using the total water when only part was collected over the test time.
  • Mixing per m³ and per Nm³ values.

Assumptions and limits

  • Dry gas at the meter unless the wet meter is chosen, when the gas is taken as saturated at the meter temperature; no heat loss.
  • If the condensate's latent heat exceeds the heat measured, no net value is shown.
  • Normal conditions 0 °C, 101.325 kPa.

References

  • Junkers (Boys) gas calorimeter heat balance (textbook)
  • Latent heat of water at 25 °C from IAPWS-IF97

Questions and answers

What does 10 L of gas heating 6 kg of water by 15 K give?

376.8 kJ. At 15 °C and 1023 mbar the 10 L is 9.57 L at 0 °C and 1 atm, so GCV = 39.4 MJ/Nm³; with 16 g of condensate the NCV is 35.3 MJ/Nm³.

Why correct the volume?

A gas meter reads the volume at its own pressure and temperature; calorific values are quoted per normal cubic metre.

What is the condensate for?

It is the water formed by burning the hydrogen; its latent heat is the difference between gross and net values.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.