Worked example
Example: Indian coal dry: FC 40 %, VM 25 %, ash 35 %; 10 % moisture. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fixed carbon, dry basis | 40.000 % |
| Volatile matter, dry basis | 25.000 % |
| Ash, dry basis | 35.000 % |
| Total moisture, as received | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gross calorific value, dry basis | 17,769 kJ/kg |
| Gross calorific value, as received | 15,992 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(GCV_d\,[\mathrm{MJ/kg}] = 0.3536\,FC + 0.1559\,VM - 0.0078\,ASH \quad (\%\ \text{dry}) \qquad GCV_{ar} = GCV_d\,(1 - M)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(FC\) | fixed carbon, dry basis | – |
| \(VM\) | volatile matter, dry basis | – |
| \(ASH\) | ash, dry basis | – |
| \(M\) | total moisture as received | – |
| \(GCV_d\) | GCV dry basis | J/kg |
| \(GCV_{ar}\) | GCV as received | J/kg |
Method and standards
Parikh, Channiwala and Ghosal (2005) correlation of higher heating value with proximate analysis on a dry basis; as-received value by the basis relation.
Where it is used
- Screening coals and biomass when only proximate analysis is available.
- Checking a lab GCV for gross errors.
- First estimates for new fuels.
Common mistakes
- Using air-dried or as-received percentages in the dry-basis formula.
- Using the estimate for guarantees or efficiency tests.
- Forgetting the result is gross (higher) calorific value.
Assumptions and limits
- Dry-basis proximate analysis adding to 100 % (within ±2 %; it is normalised, with a note above ±0.5 %); correlation accuracy a few per cent.
- The correlation was fitted to a wide set of coals and biomasses; very high-ash fuels (above about 40 % ash, as some Indian coals) may lie outside the fitted data and are less certain.
- An air-dried or as-received analysis entered as dry cannot be detected; convert it to dry first.
References
- J. Parikh
- S.A. Channiwala
- G.K. Ghosal
- Fuel 84 (2005) 487–494
Questions and answers
Can I estimate GCV without a bomb calorimeter?
Roughly, from the proximate analysis. Indian coal with 40 % fixed carbon, 25 % volatiles and 35 % ash (dry) gives 17.8 MJ/kg dry, 16.0 MJ/kg as received at 10 % moisture.
How accurate is it?
The authors report an average error of a few per cent over many coals and biomasses; individual fuels can be further off.
Which basis?
The correlation uses the dry-basis proximate analysis; the as-received value scales by (1 − moisture).
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.