FireCADCalc

GCV from Proximate Analysis (Parikh Correlation)

Estimates the gross calorific value of coal or biomass from its proximate analysis (fixed carbon, volatile matter, ash) by the Parikh, Channiwala and Ghosal correlation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperBoilerBoiler attendant and boiler operator examinations

Inputs

Examples: Indian coal dry: FC 40 %, VM 25 %, ash 35 %; 10 % moistureImported coal dry: 52 %, 36 %, 12 %; 15 %Rice husk dry: 15 %, 65 %, 20 %; 10 %

Results

An estimate: the correlation's average error is a few per cent. Use a bomb-calorimeter value for guarantees and efficiency tests.

Gross calorific value, dry basis23,906kJ/kg
Gross calorific value, as received20,320kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal dry: FC 40 %, VM 25 %, ash 35 %; 10 % moisture. The inputs, in the units selected above:

InputValue
Fixed carbon, dry basis40.000 %
Volatile matter, dry basis25.000 %
Ash, dry basis35.000 %
Total moisture, as received10.000 %

Applying the formula below gives:

ResultValue
Gross calorific value, dry basis17,769 kJ/kg
Gross calorific value, as received15,992 kJ/kg

Open this example in the calculator and change any input.

Formula

\(GCV_d\,[\mathrm{MJ/kg}] = 0.3536\,FC + 0.1559\,VM - 0.0078\,ASH \quad (\%\ \text{dry}) \qquad GCV_{ar} = GCV_d\,(1 - M)\)

Variables

Symbol Meaning SI unit
\(FC\) fixed carbon, dry basis –
\(VM\) volatile matter, dry basis –
\(ASH\) ash, dry basis –
\(M\) total moisture as received –
\(GCV_d\) GCV dry basis J/kg
\(GCV_{ar}\) GCV as received J/kg

Method and standards

Parikh, Channiwala and Ghosal (2005) correlation of higher heating value with proximate analysis on a dry basis; as-received value by the basis relation.

Where it is used

  • Screening coals and biomass when only proximate analysis is available.
  • Checking a lab GCV for gross errors.
  • First estimates for new fuels.

Common mistakes

  • Using air-dried or as-received percentages in the dry-basis formula.
  • Using the estimate for guarantees or efficiency tests.
  • Forgetting the result is gross (higher) calorific value.

Assumptions and limits

  • Dry-basis proximate analysis adding to 100 % (within ±2 %; it is normalised, with a note above ±0.5 %); correlation accuracy a few per cent.
  • The correlation was fitted to a wide set of coals and biomasses; very high-ash fuels (above about 40 % ash, as some Indian coals) may lie outside the fitted data and are less certain.
  • An air-dried or as-received analysis entered as dry cannot be detected; convert it to dry first.

References

  • J. Parikh
  • S.A. Channiwala
  • G.K. Ghosal
  • Fuel 84 (2005) 487–494

Questions and answers

Can I estimate GCV without a bomb calorimeter?

Roughly, from the proximate analysis. Indian coal with 40 % fixed carbon, 25 % volatiles and 35 % ash (dry) gives 17.8 MJ/kg dry, 16.0 MJ/kg as received at 10 % moisture.

How accurate is it?

The authors report an average error of a few per cent over many coals and biomasses; individual fuels can be further off.

Which basis?

The correlation uses the dry-basis proximate analysis; the as-received value scales by (1 − moisture).

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.