Worked example
Example: Biogas 500 m3/h at 3 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Actual flow at the meter | 500.00 m³/h |
| Line pressure | 1.9868 bar g |
| Gas temperature | 30.000 °C |
| Compressibility factor | 0.99500 - |
| Standard reference temperature | 15.000 °C |
| Water vapour in the gas, by volume (0 = dry) | 0 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Normal flow (0 °C, 1 atm, dry if water vapour is entered) | 1,340.6 Nm³/h |
| Standard flow (at the standard temperature, 1 atm) | 1,414.2 m³/h |
| Correction factor to normal | 2.6812 |
Open this example in the calculator and change any input.
Formula
\(f = \frac{p}{p_n}\frac{T_n}{T}\frac{1 - y_w}{Z}, \quad \dot V_n = f\,\dot V, \quad \dot V_s = \dot V_n\,\frac{T_s}{T_n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Actual flow at the meter | m³/s |
| \(p\) | Line pressure (absolute) | Pa |
| \(T\) | Gas temperature | K |
| \(Z\) | Compressibility factor | - |
| \(\dot V_n\) | Normal flow (0 °C, 1 atm) | Nm³/s |
| \(\dot V_s\) | Standard flow (15 °C, 1 atm) | m³/s |
| \(f\) | Correction factor to normal | - |
| \(p_n\), \(T_n\) | normal pressure and temperature, 101.325 kPa and 273.15 K | Pa, K |
| \(T_s\) | standard reference temperature (15 °C default) | K |
| \(y_w\) | water vapour in the gas by volume (0 = dry) | - |
Method and standards
Real-gas law with a compressibility factor; the standard volume is at the reference temperature you choose and 1 atm.
Where it is used
- Fuel gas billing checks.
- Boiler fuel measurement.
Common mistakes
- Gauge pressure used as absolute.
Assumptions and limits
- Dry gas unless a water vapour share is entered, which is then removed from the normal and standard volumes.
- The line pressure is shown as gauge by default; the calculation uses absolute pressure.
- The standard pressure is 1 atm (101.325 kPa); a 60 °F contract at 14.73 psia differs by about 0.2 %.
References
- Real-gas law V_n = V (p/p_n)(T_n/T)/Z
Questions and answers
Normal or standard?
Normal is 0 °C; standard is commonly 15 °C (some contracts use 20 °C or 60 °F): check the contract.
Compressibility?
Close to 1 at low pressure; matters at a few bar and above for natural gas.
Biogas?
Same correction; also remove the water vapour for dry volume.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.