Meter and pump volumes at the heating temperature; burners are rated by mass or by volume at 60 °F.

API gravity15.896
Expansion factor per °F (× 1.8 for per K)4.0000e-04
Density at 60 °F959.04kg/m³
Density at temperature897.98kg/m³
Volume flow at 60 °F2,085.4L/h
Volume flow at temperature2,227.2L/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 1,000 lb/h, SG 0.91, 168 °F. The inputs, in the units selected above:

InputValue
Fuel oil flow453.59 kg/h
Specific gravity at 60/60 °F0.91000 -
Oil temperature75.556 °C

Applying the formula below gives:

ResultValue
API gravity23.995
Expansion factor per °F (× 1.8 for per K)4.0000e-04
Density at 60 °F909.09 kg/m³
Density at temperature871.44 kg/m³
Volume flow at 60 °F498.95 L/h
Volume flow at temperature520.51 L/h

Open this example in the calculator and change any input.

Formula

\(v_t = v_{60}[1 + E(t - 60)]\ (t\ \text{in °F}), \quad °API = \frac{141.5}{SG} - 131.5, \quad \rho_{60} = 999.0\,SG, \quad \rho_t = \frac{\rho_{60}}{1 + E(t - 60)}\)

Variables

Symbol Meaning SI unit
\(W\) Fuel oil flow kg/s
\(SG\) Specific gravity at 60/60 °F -
\(t\) Oil temperature K
\(°API\) API gravity -
\(E\) Expansion factor per °F (multiply by 1.8 for per K) 1/°F
\(\rho_{60}\) Density at 60 °F kg/m³
\(\rho_t\) Density at temperature kg/m³
\(\dot V_{60}\) Volume flow at 60 °F m³/s
\(\dot V_t\) Volume flow at temperature m³/s

Method and standards

Ganapathy's Eq. (23) with the expansion factor chosen by °API band from his Table 3.8 (not reproduced here). Water at 60 °F is taken as 999.0 kg/m³. The volume correction tables of ASTM D1250 / API MPMS 11.1 are not used.

Where it is used

  • Fuel oil pump and meter sizing.
  • Day-tank stock correction.

Common mistakes

  • Applying a water expansion coefficient.
  • Mixing °F and °C.

Assumptions and limits

  • Linear expansion with temperature and a constant factor per °API band, so the result steps slightly at the band edges.
  • Outside the table's °API bands (below 0 or above 94 °API) the end-band factor is used and a note appears.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q3.21
  • Eq. (23) and Table 3.8 (expansion factors for fuel oils)

Questions and answers

Why does volume change?

Fuel oil expands about 0.04 % per °F; heated to 168 °F it takes about 4 % more volume.

What does Ganapathy's example give?

1,000 lb/h of SG 0.91 oil: 2.2 gpm at 60 °F and 2.29 gpm at 168 °F.

Is E per °F?

Yes, as tabulated; the calculator converts temperatures.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.