FireCADCalc

Combustion Temperature without a Fuel Analysis

Adiabatic combustion temperature from LHV, HHV, excess air, air preheat and ash by Ganapathy's MMBtu energy balance, with a dissociation allowance.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileBurner and furnace

Inputs

Examples: Ganapathy: fuel oil, 15 %, 300 °F airCoal 25 % excess, 10 % ash

Results

Temperature rise of the products1,886.9K
Adiabatic combustion temperature1,913.6°C
Estimated actual combustion temperature1,838.1°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: fuel oil, 15 %, 300 °F air. The inputs, in the units selected above:

InputValue
Lower heating value39.542 MJ/kg
Higher heating value41.868 MJ/kg
Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb)Furnace oil and lignite (745)
Excess air15.000 %
Combustion air temperature148.89 °C
Reference (ambient) temperature26.667 °C
Ash in the fuel0 %
Air specific heat1.0467 kJ/(kg·K)
Mean specific heat of the products1.3398 kJ/(kg·K)
Allowance for dissociation and radiation4.0000 %

Applying the formula below gives:

ResultValue
Temperature rise of the products1,886.9 K
Adiabatic combustion temperature1,913.6 °C
Estimated actual combustion temperature1,838.1 °C

Open this example in the calculator and change any input.

Formula

\(\Delta t_c = \frac{LHV + A\alpha\,HHV\,c_{pa}(t_a - t_{ref})}{(1 - a + A\alpha\,HHV)\,c_{pg}}, \quad \alpha = 1 + EA\)

\(t_c = t_{ref} + \Delta t_c, \quad t_c' = t_{ref} + \Delta t_c\,(1 - \delta)\)

\(A\) is converted from lb/MMBtu to kg/J before use.

Variables

Symbol Meaning SI unit
\(LHV\) Lower heating value J/kg
\(HHV\) Higher heating value J/kg
\(A\) theoretical dry air per MMBtu fired for the fuel chosen (Ganapathy Table 2.4) lb/MMBtu
\(EA\) Excess air -
\(t_a\) Combustion air temperature K
\(t_{ref}\) Reference (ambient) temperature K
\(a\) Ash in the fuel -
\(c_{pa}\) Air specific heat J/(kg·K)
\(c_{pg}\) Mean specific heat of the products J/(kg·K)
\(\delta\) Allowance for dissociation and radiation -
\(\Delta t_c\) Temperature rise of the products K
\(t_c\) Adiabatic combustion temperature K
\(t_c'\) Estimated actual combustion temperature K

Method and standards

Ganapathy's Eq. (11), written as a rise above the reference temperature.

Where it is used

  • Burner and furnace checks.
  • Refractory selection.

Common mistakes

  • Using the adiabatic value as furnace exit temperature.
  • Mixing HHV and LHV.

Assumptions and limits

  • Mean product specific heat constant.
  • Fuel sensible heat, air humidity and the sensible heat carried away by ash are neglected.
  • The LHV must not exceed the HHV.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.15
  • Eq. (11)
  • and Table 2.4

Questions and answers

Why reduce by 3–5 %?

Dissociation and radiation keep real flames below the adiabatic value. The allowance reduces the rise above the reference temperature, not the absolute temperature.

Why is the denominator 1 + air?

One kilogram of fuel plus A·α·HHV kilograms of air make the products; ash leaves as solids.

What specific heats should I use?

Ganapathy uses 0.25 Btu/lb·°F for air and 0.32 for the products (1047 and 1340 J/kg·K).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.