FireCADCalc

Bomb Calorimeter Gross Calorific Value

Gross calorific value of a solid or liquid fuel from a bomb calorimeter test: water and water equivalent, temperature rise, cooling correction and fuse or acid corrections, with the net value.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalPulp and paperIAPWS-IF97 (water and steam)Burner and furnaceBoiler attendant and boiler operator examinations

Inputs

Examples: 1 g coal, 2 kg water + 0.5 kg, 25.0 to 27.5 °C, 0.02 K cooling0.8 g oil, 2.2 kg + 0.6 kg, 3.2 K rise, 60 J fuse, H 12 %1.2 g biomass, 2 kg + 0.45 kg, 2.1 K, 40 J, H 6 %, moisture 10 %

Mass of water with the same heat capacity as the bomb, bucket and stirrer.
Added to the observed rise for heat lost while the temperature was rising.

Net value

Results

The bomb gives the gross value at constant volume, on the basis of the sample burnt (often air-dried, not as fired); the net value subtracts the latent heat (at 25 °C) of the water formed from hydrogen and of the moisture.

Corrected temperature rise3.2150K
Heat released by the fuel37.630kJ
Gross calorific value47,037kJ/kg
Net calorific value44,419kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 g coal, 2 kg water + 0.5 kg, 25.0 to 27.5 °C, 0.02 K cooling. The inputs, in the units selected above:

InputValue
Mass of fuel burnt1.0000 g
Mass of water in the calorimeter2.0000 kg
Water equivalent of the calorimeter0.50000 kg
Initial temperature25.000 °C
Final (highest) temperature27.500 °C
Cooling correction0.020000 K
Specific heat of water4.1868 kJ/(kg·K)
Fuse wire, thread and acid corrections0 J
Hydrogen in the fuel, same basis as the sample (for the net value)4.0000 %
Moisture in the sample burnt (for the net value)0 %

Applying the formula below gives:

ResultValue
Corrected temperature rise2.5200 K
Heat released by the fuel26.377 kJ
Gross calorific value26,377 kJ/kg
Net calorific value25,504 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\Delta T = T_2 - T_1 + T_c\)

\(GCV = \frac{(m_w + m_e)\, c_w\, \Delta T - Q_c}{m_f}\)

\(NCV = GCV - \left(\frac{M_{H_2O}}{M_{H_2}} H + M\right) h_{fg,25}\)

Variables

Symbol Meaning SI unit
\(m_f\) Mass of fuel burnt kg
\(m_w\) Mass of water in the calorimeter kg
\(m_e\) Water equivalent of the calorimeter kg
\(T_1\) Initial temperature K
\(T_2\) Final (highest) temperature K
\(T_c\) Cooling correction K
\(c_w\) Specific heat of water J/(kg·K)
\(Q_c\) Fuse wire, thread and acid corrections J
\(H\) Hydrogen in the fuel (for the net value) -
\(M\) Moisture in the fuel (for the net value) -
\(\Delta T\) Corrected temperature rise K
\(Q\) Heat released by the fuel J
\(GCV\) Gross calorific value J/kg
\(NCV\) Net calorific value J/kg

Method and standards

Heat released by the sample equals the heat taken up by the water and the calorimeter (water equivalent), less the heat from the fuse wire, thread and acid formation.

Worked example

1 g of coal is burnt in a bomb calorimeter holding 2 kg of water; water equivalent 0.5 kg. The temperature rises from 25.0 °C to 27.5 °C; cooling correction 0.02 K.

  • Corrected rise = 2.5 + 0.02 = 2.52 K
  • Heat = (2 + 0.5) × 4.1868 × 2.52 = 26.38 kJ
  • GCV = 26.38 kJ / 0.001 kg = 26 377 kJ/kg = 6300 kcal/kg
  • With 4 % hydrogen: NCV = 26 377 − 8.94 × 0.04 × 2442 = 25 504 kJ/kg

Where it is used

  • Boiler attendant and operator examinations.
  • Fuel laboratory checks of coal, oil and biomass.
  • Understanding a coal test certificate.

Common mistakes

  • Leaving out the water equivalent.
  • Reading GCV as NCV.
  • Forgetting the cooling correction on a long test.

Assumptions and limits

  • Constant-volume gross value; the small difference from constant-pressure GCV is ignored.
  • Corrections entered by the user.
  • The net value is a simple latent-heat deduction from the constant-volume gross value. The net value at constant pressure defined in ISO 1928 and ASTM D5865 adds small terms for oxygen and nitrogen, so it differs slightly; use the standard's own procedure for a reported result.
  • Hydrogen and moisture must be on the basis of the sample burnt (often air-dried); convert to as fired with the fuel basis conversion calculator.

References

  • Bomb calorimeter heat balance (textbook; principle of ISO 1928 and ASTM D5865)
  • Latent heat of water at 25 °C from IAPWS-IF97

Questions and answers

What GCV does a 1 g sample give with 2 kg water, 0.5 kg water equivalent and a 2.5 K rise?

With 0.02 K cooling correction the rise is 2.52 K: 2.5 kg × 4.1868 × 2.52 = 26.38 kJ, so GCV = 26.38 MJ/kg (6300 kcal/kg).

What is the water equivalent?

The mass of water with the same heat capacity as the bomb, bucket and stirrer; it is found by burning a standard such as benzoic acid.

How is the net value found?

The water formed from the hydrogen (8.94 kg per kg of H) and the moisture are taken as leaving as vapour: NCV = GCV − (8.94 H + M) × 2442 kJ/kg.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators