Boiler Banking (Hot Standby) Fuel Loss

Fuel burnt to keep a boiler banked (hot standby) from the full-load heat input, the standing loss share, the banked hours and the fuel calorific value.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: 25 MW boiler, 1000 hBagasse boiler

Results

Measure the standing loss by the fuel burnt over a banked period; insulation and closed dampers lower it.

Energy lost1,728.0GJ
Fuel burnt180.00t
Cost324,000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 25 MW boiler, 1000 h. The inputs, in the units selected above:

InputValue
Full-load heat input25.000 MW
Standing loss (share of full-load input)3.0000 %
Hours banked1,000.0 h
Fuel GCV23,000 kJ/kg
Fuel price per tonne9,000.0 -

Applying the formula below gives:

ResultValue
Energy lost2,700.0 GJ
Fuel burnt117.39 t
Cost1,056,522

Open this example in the calculator and change any input.

Formula

\(E = \dot Q_{100}\,l\,t, \quad M = \frac{E}{GCV}, \quad C = \frac{M}{1000\ \text{kg/t}}\,c\)

Variables

Symbol Meaning SI unit
\(\dot Q_{100}\) Full-load heat input W
\(l\) Standing loss (share of full-load input) -
\(t\) Hours banked s
\(GCV\) Fuel GCV J/kg
\(c\) Fuel price per tonne -
\(E\) Energy lost J
\(M\) Fuel burnt kg
\(C\) Cost -

Method and standards

Definitions. The standing loss has no general published value; measure it as the fuel burnt over a banked period divided by the full-load fuel rate.

Where it is used

  • Standby policy.
  • Energy audits.

Common mistakes

  • Standing loss as share of output.

Assumptions and limits

  • Constant loss. The input is capped at 20 % of full-load input as a plausibility limit; real standing losses are a few per cent with dampers closed.

References

  • Energy balance definitions; standing loss from a site measurement of fuel burnt while banked

Questions and answers

Bank or shut down?

Compare banking fuel with start-up fuel and the risk of a slow restart.

Typical standing loss?

A few per cent of full-load input with dampers closed.

Why close dampers?

Natural draught pulls cold air through a hot boiler.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.