FireCADCalc

Sensible Heat Loss in Ash (Bottom and Fly Ash)

Boiler efficiency loss from the heat carried away by hot bottom ash and fly ash, from the ash content, split, temperatures and specific heat (ASME PTC 4).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperASME PTC 4 (fired steam generators)Boiler

Inputs

Examples: Indian coal, bottom ash 600 °C, fly ash 140 °CAFBC bed ash at 850 °C, 40 % bottomOil, negligible ash

ASME PTC 4 uses 25 °C.
FireCAD uses 0.2 Btu/(lb·°F) = 0.837 kJ/(kg·K) for coal and biomass ash; enter your own value if you have one.

Results

Sensible heat loss in ash, % of heat input0.93232%
Of which in bottom ash0.75967%
Of which in fly ash0.17265%
Residue per kg of fuel0.41237kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Indian coal, bottom ash 600 °C, fly ash 140 °C. The inputs, in the units selected above:

InputValue
Ash in the fuel, as fired35.000 %
Share of ash leaving as fly ash80.000 %
Carbon in the residue2.0000 %
Bottom ash temperature leaving the furnace600.00 °C
Fly ash temperature (gas temperature leaving the boiler)140.00 °C
Reference temperature25.000 °C
Mean specific heat of the residue0.83736 kJ/(kg·K)
Gross calorific value of the fuel, as fired18,600 kJ/kg

Applying the formula below gives:

ResultValue
Sensible heat loss in ash, % of heat input0.33282 %
Of which in bottom ash0.18490 %
Of which in fly ash0.14792 %
Residue per kg of fuel0.35714 kg/kg

Open this example in the calculator and change any input.

Formula

\(m_r = \frac{A}{1 - c_r}\)

\(L_b = \frac{m_r\,(1 - x_f)\,c_{p,r}\,(T_b - T_{ref})}{GCV} \qquad L_f = \frac{m_r\,x_f\,c_{p,r}\,(T_f - T_{ref})}{GCV} \qquad L_{ash} = L_b + L_f\)

Variables

Symbol Meaning SI unit
\(A\) ash in fuel, as fired –
\(x_f\) share of ash leaving as fly ash –
\(c_r\) carbon in residue –
\(T_b\) bottom ash temperature leaving K
\(T_f\) fly ash temperature (flue gas leaving) K
\(T_{ref}\) reference temperature, 25 °C in PTC 4 K
\(c_{p,r}\) mean specific heat of residue J/(kg·K)
\(GCV\) gross calorific value J/kg
\(L_{ash}\) sensible heat loss in ash –
\(L_b\) of which in bottom ash –
\(L_f\) of which in fly ash –
\(m_r\) residue per kg of fuel kg/kg

Method and standards

Sensible heat of residue as in ASME PTC 4: residue mass times mean specific heat times its rise above the reference temperature, split into bottom ash and fly ash. The default specific heat is 0.2 Btu/(lb·°F) = 837 J/(kg·K) for coal and biomass ash (FireCAD practice, confirmed 2026-11-11).

Where it is used

  • Complete loss accounting in efficiency tests of high-ash coal, lignite and biomass boilers.
  • Comparing dry and wet bottom-ash handling.
  • Fluidised-bed boilers that drain hot bed material.

Common mistakes

  • Using the furnace temperature for bottom ash that cools on a grate or in a hopper before it leaves.
  • Applying the bottom-ash temperature to all the ash.
  • Ignoring bed drain and economiser or air heater hopper ash in fluidised beds.

Assumptions and limits

  • One mean specific heat for both ash streams; ash temperatures below the reference are rejected.
  • Fly ash leaves at the flue gas temperature.

References

  • ASME PTC 4-2013 Fired Steam Generators (sensible heat of residue)
  • BIS IS 8753 (boiler efficiency)

Questions and answers

How big is the ash sensible heat loss?

Usually small. Coal with 35 % ash, 20 % of it leaving as bottom ash at 600 °C and the rest as fly ash at 140 °C, loses 0.33 % of the heat input. It matters most for high-ash coal with dry bottom-ash removal and for hot bed drain from fluidised beds.

What specific heat should I use?

FireCAD uses 0.2 Btu/(lb·°F) = 0.837 kJ/(kg·K) for both coal and biomass ash. ASME PTC 4 gives a temperature-dependent curve; enter your own value if you have a measured or code figure.

What temperature for bottom ash?

The temperature at which it leaves the boiler boundary: several hundred °C from a dry hopper or grate, much lower if it is quenched in a water seal inside the boundary.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.