FireCADCalc

Water-Side Heat Transfer Coefficient: Quick Estimate

Tube-side heat transfer coefficient of water in turbulent flow from velocity, bore and temperature by Ganapathy's simplified expression for economisers.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperIAPWS-IF97 (water and steam)Economiser and air preheater

Inputs

Examples: Ganapathy: 50,000 lb/h at 250 °F in 2.9 inEconomiser 15 t/h at 180 °C in 40 mm

Results

Water-side resistance is usually small next to the gas side; the estimate suits turbulent flow (velocities above about 0.3 m/s).

Water velocity3.7381m/s
Tube-side coefficient27,033W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 50,000 lb/h at 250 °F in 2.9 in. The inputs, in the units selected above:

InputValue
Water flow per tube (or per pass)22,680 kg/h
Tube inner diameter73.660 mm
Mean water temperature121.11 °C

Applying the formula below gives:

ResultValue
Water velocity1.5690 m/s
Tube-side coefficient9,149.7 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(h_i = (150 + 1.55\,t)\,\frac{V^{0.8}}{d_i^{0.2}} \ \ (\mathrm{Btu/ft^2\,h\,°F};\ t\ °F,\ V\ ft/s,\ d_i\ in)\)

Variables

Symbol Meaning SI unit
\(W\) Water flow per tube (or per pass) kg/s
\(d_i\) Tube inner diameter m
\(t\) Mean water temperature K
\(V\) Water velocity m/s
\(h_i\) Tube-side coefficient W/(m²·K)

Method and standards

Ganapathy's Eq. (13).

Where it is used

  • Economiser and water heater design.
  • Quick checks of vendor data.

Common mistakes

  • Using it for laminar flow.
  • Entering total flow for a multi-tube pass.

Assumptions and limits

  • Ganapathy's expression is dimensional (°F, ft/s, inches, Btu/(ft²·h·°F)); the page converts to and from SI through the unit registry.

  • Turbulent flow only. No Reynolds number is computed; the page warns below about 0.3 m/s, where the flow may not be turbulent.

  • Turbulent single-phase water.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q4.03b
  • Eq. (13)
  • Water specific volume from IAPWS-IF97 (saturated liquid at t)

Questions and answers

Where does it come from?

Dittus–Boelter with water's properties folded into (150 + 1.55 t), t in °F.

What does Ganapathy's example give?

50,000 lb/h at 250 °F in a 2.9 in bore: about 1,590 Btu/ft²·h·°F with his rounded velocity of 5.05 ft/s; the exact bore area gives 5.15 ft/s and about 1,610 (9.1 kW/m²·K).

Why does it barely matter?

Gas-side coefficients are 10–100 times lower, so the overall U is set by the gas side.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.