Worked example
Example: 300 kW/m2 at 70 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat flux | 300.00 kW/m² |
| Pressure (absolute) | 70.000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wall superheat, Jens–Lottes | 5.9826 K |
| Wall superheat, Thom | 5.5488 K |
| Saturation temperature | 285.83 °C |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{JL} = 25\,q^{1/4}e^{-p/62}, \quad \Delta T_{Th} = 22.65\,q^{1/2}e^{-p/87}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q\) | Heat flux | W/m² |
| \(p\) | Pressure (absolute) | Pa |
| \(\Delta T_{JL}\) | Wall superheat, Jens–Lottes | K |
| \(\Delta T_{Th}\) | Wall superheat, Thom | K |
| \(T_{sat}\) | Saturation temperature | K |
Method and standards
Jens–Lottes; Thom.
Where it is used
- Evaporator tube temperature checks.
Common mistakes
- Heat flux in kW/m² in the formula.
Assumptions and limits
- Water; nucleate boiling.
- Data ranges: Jens–Lottes about 7–172 bar, Thom about 52–138 bar (Collier and Thome). The calculator warns outside them.
References
- Jens and Lottes (1951) ΔT = 25 q^¼ e^{−p/62}; Thom et al. (1965) ΔT = 22.65 q^½ e^{−p/87} (q in MW/m², p in bar; Collier and Thome)
Questions and answers
Why two correlations?
They come from different data sets. Thom predicts higher superheat than Jens–Lottes above a crossover flux (about 0.4 MW/m² at 70 bar) and lower superheat below it.
Use?
To find the inner wall temperature of evaporator tubes for metal temperature checks.
Units?
They are dimensional: heat flux in MW/m² and pressure in bar.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.