Wall Superheat in Boiling Water (Jens–Lottes and Thom)

Wall superheat above saturation for nucleate boiling of water in tubes from the heat flux and pressure by the Jens–Lottes and Thom correlations.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: 300 kW/m2 at 70 bar150 kW/m2 at 20 bar

Results

Both correlations are dimensional: q in MW/m², p in bar. The tube inner wall runs at T_sat plus this superheat.

The pressure is outside the Thom data range (about 52–138 bar).

Wall superheat, Jens–Lottes11.269K
Wall superheat, Thom6.9707K
Saturation temperature212.38°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 300 kW/m2 at 70 bar. The inputs, in the units selected above:

InputValue
Heat flux300.00 kW/m²
Pressure (absolute)70.000 bar

Applying the formula below gives:

ResultValue
Wall superheat, Jens–Lottes5.9826 K
Wall superheat, Thom5.5488 K
Saturation temperature285.83 °C

Open this example in the calculator and change any input.

Formula

\(\Delta T_{JL} = 25\,q^{1/4}e^{-p/62}, \quad \Delta T_{Th} = 22.65\,q^{1/2}e^{-p/87}\)

Variables

Symbol Meaning SI unit
\(q\) Heat flux W/m²
\(p\) Pressure (absolute) Pa
\(\Delta T_{JL}\) Wall superheat, Jens–Lottes K
\(\Delta T_{Th}\) Wall superheat, Thom K
\(T_{sat}\) Saturation temperature K

Method and standards

Jens–Lottes; Thom.

Where it is used

  • Evaporator tube temperature checks.

Common mistakes

  • Heat flux in kW/m² in the formula.

Assumptions and limits

  • Water; nucleate boiling.
  • Data ranges: Jens–Lottes about 7–172 bar, Thom about 52–138 bar (Collier and Thome). The calculator warns outside them.

References

  • Jens and Lottes (1951) ΔT = 25 q^¼ e^{−p/62}; Thom et al. (1965) ΔT = 22.65 q^½ e^{−p/87} (q in MW/m², p in bar; Collier and Thome)

Questions and answers

Why two correlations?

They come from different data sets. Thom predicts higher superheat than Jens–Lottes above a crossover flux (about 0.4 MW/m² at 70 bar) and lower superheat below it.

Use?

To find the inner wall temperature of evaporator tubes for metal temperature checks.

Units?

They are dimensional: heat flux in MW/m² and pressure in bar.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.