Worked example
Example: Water at 1 atm, C 0.149. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure (absolute) | 1.0132 bar |
| Constant (0.149 Lienhard flat heater; 0.131 Zuber) | 0.14900 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation temperature | 99.974 °C |
| Surface tension (IAPWS) | 0.058917 N/m |
| Critical heat flux | 1,260.7 kW/m² |
Open this example in the calculator and change any input.
Formula
\(q''_{max} = C\, h_{fg}\, \rho_v \left[\frac{\sigma g (\rho_l - \rho_v)}{\rho_v^2}\right]^{1/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure (absolute) | Pa |
| \(C\) | Constant (0.149 Lienhard flat heater; 0.131 Zuber) | - |
| \(T_{sat}\) | Saturation temperature | K |
| \(\sigma\) | Surface tension (IAPWS) | N/m |
| \(q''_{max}\) | Critical heat flux | W/m² |
Method and standards
Hydrodynamic instability of the vapour columns.
Where it is used
- Boiler tube and heater design limits.
- Heat transfer examinations.
Common mistakes
- Applying pool values to tubes.
- Ignoring subcooling and pressure.
Assumptions and limits
- Saturated pool boiling, large surface.
References
- N. Zuber (1959); J.H. Lienhard and V.K. Dhir (1973)
- constant 0.149; Incropera
- DeWitt
- Bergman and Lavine
- Fundamentals of Heat and Mass Transfer
- ch. 10
- IAPWS-IF97 and IAPWS R1-76(2014) surface tension
Questions and answers
What is the CHF of water at 1 atm?
About 1.26 MW/m² with 0.149.
Why does it rise with pressure at first?
Denser vapour carries more latent heat away, up to about a third of the critical pressure.
Why does it matter?
Above it a vapour blanket forms and the wall temperature jumps: burnout.