FireCADCalc

Critical Heat Flux in Pool Boiling (Zuber–Lienhard)

Peak (critical) heat flux for pool boiling of water at a pressure from saturation properties and IAPWS surface tension, by the Zuber–Lienhard correlation.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Water at 1 atm, C 0.14910 bar(a), C 0.1491 atm, Zuber 0.131

Results

Saturated pool boiling on a large horizontal surface; flow boiling in tubes has its own critical heat flux.

Saturation temperature99.974°C
Surface tension (IAPWS)0.058917N/m
Critical heat flux1,108.4kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water at 1 atm, C 0.149. The inputs, in the units selected above:

InputValue
Pressure (absolute)1.0132 bar
Constant (0.149 Lienhard flat heater; 0.131 Zuber)0.14900 -

Applying the formula below gives:

ResultValue
Saturation temperature99.974 °C
Surface tension (IAPWS)0.058917 N/m
Critical heat flux1,260.7 kW/m²

Open this example in the calculator and change any input.

Formula

\(q''_{max} = C\, h_{fg}\, \rho_v \left[\frac{\sigma g (\rho_l - \rho_v)}{\rho_v^2}\right]^{1/4}\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (absolute) Pa
\(C\) Constant (0.149 Lienhard flat heater; 0.131 Zuber) -
\(T_{sat}\) Saturation temperature K
\(\sigma\) Surface tension (IAPWS) N/m
\(q''_{max}\) Critical heat flux W/m²

Method and standards

Hydrodynamic instability of the vapour columns.

Where it is used

  • Boiler tube and heater design limits.
  • Heat transfer examinations.

Common mistakes

  • Applying pool values to tubes.
  • Ignoring subcooling and pressure.

Assumptions and limits

  • Saturated pool boiling, large surface.

References

  • N. Zuber (1959); J.H. Lienhard and V.K. Dhir (1973)
  • constant 0.149; Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 10
  • IAPWS-IF97 and IAPWS R1-76(2014) surface tension

Questions and answers

What is the CHF of water at 1 atm?

About 1.26 MW/m² with 0.149.

Why does it rise with pressure at first?

Denser vapour carries more latent heat away, up to about a third of the critical pressure.

Why does it matter?

Above it a vapour blanket forms and the wall temperature jumps: burnout.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.