Critical Heat Flux: Macbeth (Tubes) and Mostinski (Pool)

Critical heat flux for boiling in a tube (Macbeth: pressure, diameter, mass velocity, quality) and in a pool (Mostinski), with a design allowance.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Ganapathy: 1000 psia, 1.5 in, 600,000 lb/(ft2 h), x 0.2 (2.43e6 Btu/(ft2 h))Ganapathy pool case: 400 psia (Mostinski 1.10e6)

Results

Laboratory correlations: real boilers allow 20–30 % less (roughness, water quality, deposits); boiler makers use their own DNB data. Macbeth here is Ganapathy's simplified form.

Latent heat1,511.9kJ/kg
Critical heat flux in the tube (Macbeth)7,684.4kW/m²
Critical heat flux in pool boiling (Mostinski)3,850.9kW/m²
Allowable tube heat flux after the reduction5,379.0kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 1000 psia, 1.5 in, 600,000 lb/(ft2 h), x 0.2 (2.43e6 Btu/(ft2 h)). The inputs, in the units selected above:

InputValue
Pressure (absolute)68.948 bar
Tube inside diameter38.100 mm
Mass velocity inside the tube813.74 kg/(m²·s)
Steam quality20.000 %
Design reduction from the correlation30.000 %

Applying the formula below gives:

ResultValue
Latent heat1,511.9 kJ/kg
Critical heat flux in the tube (Macbeth)7,684.4 kW/m²
Critical heat flux in pool boiling (Mostinski)3,850.9 kW/m²
Allowable tube heat flux after the reduction5,379.0 kW/m²

Open this example in the calculator and change any input.

Formula

\(q_c = 0.00633\times10^6\,h_{fg}\,d_i^{-0.1}\left(\frac{G}{10^6}\right)^{0.51}(1 - x)\ \ (\mathrm{Btu/(ft^2\,h)};\ h_{fg}\ \mathrm{Btu/lb},\ d_i\ \mathrm{in},\ G\ \mathrm{lb/(ft^2\,h)})\)

\(q_c = 803\,p_c\left(\frac{p}{p_c}\right)^{0.35}\left(1 - \frac{p}{p_c}\right)^{0.9}\ \ (p\ \mathrm{psia}), \qquad q_{allow} = q_{c,Macbeth}(1 - m)\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (absolute) Pa
\(d_i\) Tube inside diameter m
\(G\) Mass velocity inside the tube kg/(m²·s)
\(x\) Steam quality -
\(m\) Design reduction from the correlation -
\(h_{fg}\) Latent heat J/kg
\(q_{c,Macbeth}\) Critical heat flux in the tube (Macbeth) W/m²
\(q_{c,Mostinski}\) Critical heat flux in pool boiling (Mostinski) W/m²
\(q_{allow}\) Allowable tube heat flux after the reduction W/m²

Method and standards

Macbeth and Mostinski correlations (US units, converted).

Where it is used

  • Water-wall and generating-tube checks.
  • Fire-tube boiler heat flux limits.

Common mistakes

  • Comparing average instead of peak flux.
  • Ignoring the design reduction.

Assumptions and limits

  • Water; subcritical. The data range of the Macbeth correlation is not checked: at high mass velocity and low quality it can give very high values, so use the maker's DNB data for design.
  • Unit conversions: 1 Btu/(ft²·h) = 3.154591 W/m², 1 Btu/lb = 2326 J/kg, 1 in = 0.0254 m, 1 lb/(ft²·h) = 1.356230 × 10⁻³ kg/(m²·s), 1 psi = 6894.757 Pa.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1994)
  • Q4.47a (Macbeth correlation) and Q4.47b (Mostinski, pool boiling); IAPWS-IF97 latent heat

Questions and answers

What do Ganapathy's examples give?

Macbeth at 1,000 psia, 1.5 in tube, 600,000 lb/(ft²·h), 20 % quality: 2.43 × 10⁶ Btu/(ft²·h) (7.7 MW/m²); Mostinski at 400 psia: 1.10 × 10⁶ Btu/(ft²·h).

Why does quality lower the critical flux?

With more vapour, the liquid film on the wall is thinner and dries out at a lower heat flux.

Is the boiler at risk?

Compare the peak local heat flux (water-wall flux × peaking factor) with the allowable value.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.