Winding Pitch, Distribution and Winding Factors

Slots per pole per phase, slot angle, pitch factor, distribution factor and winding factor of a three-phase AC winding, for the fundamental or a harmonic.

Inputs

Examples: Illustrative 36 slots, 4 poles, span 8Same winding, 5th harmonic48 slots, 4 poles, span 10

Accepted: 6 to 600
Accepted: 2 to 120
Accepted: 1 to 6
Accepted: 1 to 300
Accepted: 1 to 49

Results

The EMF of a winding is reduced by short pitching (coils spanning less than a pole pitch, k_p = cos(hα/2)) and by distributing each phase over q slots (k_d = sin(hqβ/2)/(q·sin(hβ/2))), where β = 180°·P/S electrical is the slot angle. The winding factor k_w = k_p·k_d multiplies the EMF equation. Chording by about one sixth of a pole pitch nearly removes the 5th and 7th harmonics while costing only a few per cent of the fundamental. Negative factors mean the harmonic reverses sign.

Slots per pole per phase3.0000
Slot angle (electrical)20.000°
Short-pitch angle (electrical)20.000°
Pitch factor0.98481
Distribution factor0.95980
Winding factor0.94521

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 36 slots, 4 poles, span 8. The inputs, in the units selected above:

InputValue
Number of slots36.000 -
Number of poles4.0000 -
Number of phases3.0000 -
Coil span (slots)8.0000 -
Harmonic order1.0000 -

Applying the formula below gives:

ResultValue
Slots per pole per phase3.0000
Slot angle (electrical)20.000 °
Short-pitch angle (electrical)20.000 °
Pitch factor0.98481
Distribution factor0.95980
Winding factor0.94521

Open this example in the calculator and change any input.

Formula

\(k_p = \cos\frac{h\alpha}{2}, \quad k_d = \frac{\sin(hq\beta/2)}{q\sin(h\beta/2)}, \quad k_w = k_pk_d, \quad \beta = \frac{180^\circ P}{S}\)

Variables

Symbol Meaning SI unit
\(S\) Number of slots -
\(P\) Number of poles -
\(m\) Number of phases -
\(y\) Coil span (slots) -
\(h\) Harmonic order -
\(q\) Slots per pole per phase -
\(\beta\) Slot angle (electrical) rad
\(\alpha\) Short-pitch angle (electrical) rad
\(k_p\) Pitch factor -
\(k_d\) Distribution factor -
\(k_w\) Winding factor -

Method and standards

Winding factors.

Where it is used

  • Machine design and rewinding.
  • Electrical machines examinations.

Common mistakes

  • Using mechanical instead of electrical angles.
  • Counting the span in coils instead of slots.

Assumptions and limits

  • Integral or fractional-slot windings by these formulas.

References

  • AC winding pitch and distribution factors

Questions and answers

What are the factors for 36 slots, 4 poles and an 8-slot coil span?

Pitch factor 0.985, distribution factor 0.960, winding factor 0.945.

How does short pitching help?

It reduces harmonic EMFs much more than the fundamental.

What do the defaults represent?

A 36-slot, 4-pole, three-phase winding with coils spanning 8 slots (pole pitch 9), fundamental.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.