Worked example
Example: Illustrative 250 V shunt motor, 5 to 4 A field. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Armature voltage | 250.00 V |
| Armature circuit resistance | 0.060000 Ω |
| Armature current before | 120.00 A |
| Speed before | 1,200.0 rpm |
| Field current before | 5.0000 A |
| Field current after | 4.0000 A |
Applying the formula below gives:
| Result | Value |
|---|---|
| Back EMF before | 242.80 V |
| Armature current after | 150.00 A |
| Back EMF after | 241.00 V |
| Speed after | 1,488.9 rpm |
| Load torque (constant) | 231.86 N·m |
Open this example in the calculator and change any input.
Formula
\(E = V_T - I_AR_A, \quad I_{A2} = I_{A1}\frac{\phi_1}{\phi_2}, \quad \frac{n_2}{n_1} = \frac{E_2}{E_1}\frac{\phi_1}{\phi_2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_T\) | Armature voltage | V |
| \(R_A\) | Armature circuit resistance | Ω |
| \(I_{A1}\) | Armature current before | A |
| \(n_1\) | Speed before | rad/s |
| \(I_{F1}\) | Field current before | A |
| \(I_{F2}\) | Field current after | A |
| \(E_1\) | Back EMF before | V |
| \(I_{A2}\) | Armature current after | A |
| \(E_2\) | Back EMF after | V |
| \(n_2\) | Speed after | rad/s |
| \(T\) | Load torque (constant) | N·m |
Method and standards
Field weakening.
Where it is used
- DC drive speed range above base speed.
- Teaching DC machine control.
Common mistakes
- Ignoring the armature current rise.
- Assuming linear flux in a saturated machine.
Assumptions and limits
- Flux proportional to field current; constant load torque; no armature reaction.
References
- DC machine equations with linear magnetisation
Questions and answers
Why does weakening the field raise speed?
Less flux needs more speed to generate the same back EMF.
Why is losing the field dangerous?
With almost no flux, the motor races to try to build back EMF, and armature current soars.
What do the defaults represent?
An illustrative 250 V shunt motor at 1,200 rpm drawing 120 A, field reduced from 5 A to 4 A, constant-torque load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)