Worked example
Example: Illustrative 415 V delta 4-pole motor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Line voltage | 415.00 V |
| Winding connection | Delta |
| Frequency | 50.000 Hz |
| Number of poles | 4.0000 - |
| Stator bore diameter | 200.00 mm |
| Core length | 150.00 mm |
| Mean flux density in the air gap | 0.45000 T |
| Winding factor | 0.95500 - |
| Induced EMF as a share of the phase voltage | 0.97000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flux per pole | 10.603 mWb |
| Induced EMF per phase | 402.55 V |
| Turns per phase | 179.08 |
| Conductors per phase (2T) | 358.15 |
| Pole pitch | 157.08 mm |
Open this example in the calculator and change any input.
Formula
\(E_{ph} = 4.44\, f\, \Phi\, T_{ph}\, k_w, \quad \Phi = \frac{B_{av}\,\pi D L}{p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_L\) | Line voltage | V |
| \(\text{conn}\) | Winding connection | - |
| \(f\) | Frequency | 1/s |
| \(p\) | Number of poles | - |
| \(D\) | Stator bore diameter | m |
| \(L\) | Core length | m |
| \(B_{av}\) | Mean flux density in the air gap | T |
| \(k_w\) | Winding factor | - |
| \(E/V\) | Induced EMF as a share of the phase voltage | - |
| \(\Phi\) | Flux per pole | Wb |
| \(E_{ph}\) | Induced EMF per phase | V |
| \(T_{ph}\) | Turns per phase | - |
| \(Z_{ph}\) | Conductors per phase (2T) | - |
| \(\tau_p\) | Pole pitch | m |
Method and standards
EMF equation.
Where it is used
- Rewinding motors to a new voltage or frequency.
- First-pass design of a stator winding.
Common mistakes
- Using line voltage for a star winding.
- Forgetting the winding factor.
Assumptions and limits
- Sinusoidal gap flux; the EMF ratio is an estimate.
References
- EMF equation E = 4.44 f Φ T k_w and specific magnetic loading
Questions and answers
How do I calculate turns per phase for a motor?
T = E/(4.44 f Φ k_w), with E about 0.97 of the phase voltage and Φ = B_av π D L/p from the bore and core length.
What mean gap flux density should I use?
About 0.35–0.6 T for induction motors; higher values save iron but raise magnetising current.
What do the defaults represent?
An illustrative 415 V delta, 50 Hz, 4-pole motor with a 200 mm bore and 150 mm core at 0.45 T.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Sawhney, A Course in Electrical Machine Design, 6th ed. (Dhanpat Rai, 2006)