Worked example
Example: Illustrative 250 V motor, 50 to 100 A. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Terminal voltage | 250.00 V |
| Armature plus series field resistance | 0.080000 Ω |
| Known current | 50.000 A |
| Speed at the known current | 1,200.0 rpm |
| New current | 100.00 A |
| Brush drop | 2.0000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Back EMF at I₁ | 244.00 V |
| Torque at I₁ | 97.085 N·m |
| Back EMF at I₂ | 240.00 V |
| Speed at I₂ | 590.16 rpm |
| Torque at I₂ | 388.34 N·m |
Open this example in the calculator and change any input.
Formula
\(E = V_T - V_B - I(R_A + R_S), \quad \frac{n_2}{n_1} = \frac{E_2}{E_1}\frac{I_1}{I_2}, \quad T = \frac{EI}{\omega}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_T\) | Terminal voltage | V |
| \(R_A + R_S\) | Armature plus series field resistance | Ω |
| \(I_1\) | Known current | A |
| \(n_1\) | Speed at the known current | rad/s |
| \(I_2\) | New current | A |
| \(V_B\) | Brush drop | V |
| \(E_1\) | Back EMF at I₁ | V |
| \(T_1\) | Torque at I₁ | N·m |
| \(E_2\) | Back EMF at I₂ | V |
| \(n_2\) | Speed at I₂ | rad/s |
| \(T_2\) | Torque at I₂ | N·m |
Method and standards
Series motor.
Where it is used
- Traction, hoist and starter motors.
- Teaching DC machine characteristics.
Common mistakes
- Assuming constant flux as in a shunt motor.
- Running the motor without load.
Assumptions and limits
- Flux proportional to current; constant brush drop; no armature reaction.
References
- DC series motor equations (linear magnetisation)
Questions and answers
Why must a series motor never run unloaded?
Flux falls with current, so at light load speed rises without limit and can burst the armature.
Why is starting torque so high?
Torque goes as current squared, and starting current is high.
What do the defaults represent?
An illustrative 250 V series motor with 0.08 Ω total resistance and 2 V brush drop, running at 1,200 rpm at 50 A, loaded to 100 A.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)