DC Series Motor Speed and Torque at Another Load

Back EMF, speed and torque of a DC series motor at a new current from a known operating point, assuming flux proportional to current (unsaturated).

Inputs

Examples: Illustrative 250 V motor, 50 to 100 ALight load 50 to 20 ATraction motor 600 V

Accepted: 6 to 3,000 V
Accepted: 0.001 to 50 Ω
Accepted: 0.1 to 10,000 A
Accepted: 9.5493 to 9,549.3 rpm
Accepted: 0.1 to 10,000 A
Accepted: 0 to 10 V

Results

E = V_T − V_B − I(R_A + R_S) and E = Kφω with φ ∝ I below saturation, so n₂/n₁ = (E₂/E₁)(I₁/I₂) and torque Kφ I ∝ I². Series motors give high starting torque (traction, hoists, starters) and race at light load, so they must never run unloaded. With saturation torque rises more slowly than I² and speed falls less at high current.

Back EMF at I₁244.00V
Torque at I₁97.085N·m
Back EMF at I₂240.00V
Speed at I₂590.16rpm
Torque at I₂388.34N·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 V motor, 50 to 100 A. The inputs, in the units selected above:

InputValue
Terminal voltage250.00 V
Armature plus series field resistance0.080000 Ω
Known current50.000 A
Speed at the known current1,200.0 rpm
New current100.00 A
Brush drop2.0000 V

Applying the formula below gives:

ResultValue
Back EMF at I₁244.00 V
Torque at I₁97.085 N·m
Back EMF at I₂240.00 V
Speed at I₂590.16 rpm
Torque at I₂388.34 N·m

Open this example in the calculator and change any input.

Formula

\(E = V_T - V_B - I(R_A + R_S), \quad \frac{n_2}{n_1} = \frac{E_2}{E_1}\frac{I_1}{I_2}, \quad T = \frac{EI}{\omega}\)

Variables

Symbol Meaning SI unit
\(V_T\) Terminal voltage V
\(R_A + R_S\) Armature plus series field resistance Ω
\(I_1\) Known current A
\(n_1\) Speed at the known current rad/s
\(I_2\) New current A
\(V_B\) Brush drop V
\(E_1\) Back EMF at I₁ V
\(T_1\) Torque at I₁ N·m
\(E_2\) Back EMF at I₂ V
\(n_2\) Speed at I₂ rad/s
\(T_2\) Torque at I₂ N·m

Method and standards

Series motor.

Where it is used

  • Traction, hoist and starter motors.
  • Teaching DC machine characteristics.

Common mistakes

  • Assuming constant flux as in a shunt motor.
  • Running the motor without load.

Assumptions and limits

  • Flux proportional to current; constant brush drop; no armature reaction.

References

  • DC series motor equations (linear magnetisation)

Questions and answers

Why must a series motor never run unloaded?

Flux falls with current, so at light load speed rises without limit and can burst the armature.

Why is starting torque so high?

Torque goes as current squared, and starting current is high.

What do the defaults represent?

An illustrative 250 V series motor with 0.08 Ω total resistance and 2 V brush drop, running at 1,200 rpm at 50 A, loaded to 100 A.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.