Worked example
Example: Illustrative 230 V, 50 Hz motor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Supply voltage | 230.00 V |
| Supply frequency | 50.000 Hz |
| Main winding resistance (locked rotor) | 4.5000 Ω |
| Main winding reactance (locked rotor) | 3.7000 Ω |
| Auxiliary winding resistance | 9.5000 Ω |
| Auxiliary winding reactance | 3.5000 Ω |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capacitor reactance | 15.054 Ω |
| Capacitance | 211.44 µF |
| Main winding current | 39.480 A |
| Auxiliary winding current | 15.376 A |
| Voltage across the capacitor | 231.47 V |
| Line current | 42.368 A |
Open this example in the calculator and change any input.
Formula
\(X_C = X_a + \frac{R_aR_m}{X_m}, \quad C = \frac{1}{2\pi fX_C}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Supply voltage | V |
| \(f\) | Supply frequency | 1/s |
| \(R_m\) | Main winding resistance (locked rotor) | Ω |
| \(X_m\) | Main winding reactance (locked rotor) | Ω |
| \(R_a\) | Auxiliary winding resistance | Ω |
| \(X_a\) | Auxiliary winding reactance | Ω |
| \(X_C\) | Capacitor reactance | Ω |
| \(C\) | Capacitance | F |
| \(I_m\) | Main winding current | A |
| \(I_a\) | Auxiliary winding current | A |
| \(V_C\) | Voltage across the capacitor | V |
| \(I_L\) | Line current | A |
Method and standards
Start capacitor.
Where it is used
- Replacing or redesigning start capacitors.
- Teaching single-phase motor starting.
Common mistakes
- Using running (not locked-rotor) impedances.
- Choosing a capacitor voltage rating equal to the supply.
Assumptions and limits
- Standstill impedances; sinusoidal supply; magnetic coupling of windings neglected.
References
- Two-winding single-phase motor at standstill
Questions and answers
Why aim for 90° between the currents?
Starting torque is proportional to the sine of the angle between them, so 90° gives the most torque per ampere.
Why is the capacitor voltage higher than the supply?
The capacitor and the auxiliary winding form a partly resonant series circuit.
What do the defaults represent?
Illustrative locked-rotor impedances of a 230 V, 50 Hz motor: main 4.5 + j3.7 Ω, auxiliary 9.5 + j3.5 Ω.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Veinott and Martin, Fractional and Subfractional Horsepower Electric Motors, 4th ed. (McGraw-Hill, 1986)