Worked example
Example: Illustrative 460 V 4-pole machine. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Line voltage (star) | 460.00 V |
| Frequency | 60.000 Hz |
| Number of poles | 4.0000 - |
| Stator resistance per phase | 0.64100 Ω |
| Stator leakage reactance | 1.1060 Ω |
| Magnetising reactance | 26.300 Ω |
| Rotor resistance referred to stator | 0.33200 Ω |
| Rotor leakage reactance referred | 0.46400 Ω |
| Stator-to-rotor turns ratio | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thevenin voltage per phase | 254.79 V |
| Slip at maximum torque (no external R) | 20.141 % |
| Pull-out torque | 230.80 N·m |
| Starting torque without external R | 106.56 N·m |
| External resistance referred to stator | 1.3164 Ω |
| External resistance per rotor phase | 0.32909 Ω |
Open this example in the calculator and change any input.
Formula
\(s_{max} = \frac{R_2'}{\sqrt{R_{TH}^2 + (X_{TH} + X_2')^2}}, \quad T_{max} = \frac{3V_{TH}^2}{2\omega_s\left[R_{TH} + \sqrt{R_{TH}^2 + (X_{TH} + X_2')^2}\right]}, \quad R_{ext}' = \sqrt{R_{TH}^2 + (X_{TH} + X_2')^2} - R_2'\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_L\) | Line voltage (star) | V |
| \(f\) | Frequency | 1/s |
| \(p\) | Number of poles | - |
| \(R_1\) | Stator resistance per phase | Ω |
| \(X_1\) | Stator leakage reactance | Ω |
| \(X_M\) | Magnetising reactance | Ω |
| \(R_2'\) | Rotor resistance referred to stator | Ω |
| \(X_2'\) | Rotor leakage reactance referred | Ω |
| \(a\) | Stator-to-rotor turns ratio | - |
| \(V_{TH}\) | Thevenin voltage per phase | V |
| \(s_{max}\) | Slip at maximum torque (no external R) | - |
| \(T_{max}\) | Pull-out torque | N·m |
| \(T_{start}\) | Starting torque without external R | N·m |
| \(R_{ext}'\) | External resistance referred to stator | Ω |
| \(R_{ext}\) | External resistance per rotor phase | Ω |
Method and standards
Rotor resistance.
Where it is used
- Slip-ring motor starter design.
- Teaching torque-speed curves.
Common mistakes
- Forgetting to refer resistance through the turns ratio.
- Using line instead of phase voltage.
Assumptions and limits
- Steady-state equivalent circuit; constant parameters; star connection.
References
- Thevenin equivalent circuit of the induction motor
Questions and answers
Why does rotor resistance not change the maximum torque?
It only shifts the slip at which the maximum occurs; the peak depends on the stator and leakage reactances.
Why use a wound-rotor motor today?
For very heavy, high-inertia starts on weak supplies (mills, crushers), though VFDs have replaced many.
What do the defaults represent?
An illustrative 460 V, 60 Hz, 4-pole machine with the equivalent circuit R₁ 0.641, X₁ 1.106, X_M 26.3, R₂′ 0.332, X₂′ 0.464 Ω and turns ratio 2.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)