FireCADCalc

Induction Motor Torque-Speed Curve by the Kloss Formula

Synchronous speed, rated and breakdown torque, breakdown slip and the torque at any speed of an induction motor from its rating plate data by the Kloss formula.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 37 kW 4-pole at 1000 rpm200 kW 2-pole at 2900 rpm7.5 kW 6-pole 60 Hz near stall

Accepted: 0.1 to 20,000 kW
Accepted: 10 to 400 Hz
Accepted: 2 to 24
Accepted: 60 to 24,000 rpm
Accepted: 1.2 to 4
Accepted: 0 to 24,000 rpm

Results

Kloss: T = 2T_k/(s/s_k + s_k/s), with s_k = s_n(λ + √(λ² − 1)) fitted to the rated point. It describes the running region well; deep-bar and double-cage rotors give much more starting torque than Kloss predicts, so use the maker's locked-rotor torque for starting.

Synchronous speed1,500.0rpm
Rated slip1.6667%
Rated torque239.54N·m
Breakdown slip8.3333%
Breakdown speed1,375.0rpm
Torque at the speed of interest293.09N·m
Starting torque by Kloss (s = 1)103.09N·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 37 kW 4-pole at 1000 rpm. The inputs, in the units selected above:

InputValue
Rated output37.000 kW
Supply frequency50.000 Hz
Number of poles4.0000 -
Rated speed1,475.0 rpm
Breakdown torque / rated torque2.6000 -
Speed of interest1,000.0 rpm

Applying the formula below gives:

ResultValue
Synchronous speed1,500.0 rpm
Rated slip1.6667 %
Rated torque239.54 N·m
Breakdown slip8.3333 %
Breakdown speed1,375.0 rpm
Torque at the speed of interest293.09 N·m
Starting torque by Kloss (s = 1)103.09 N·m

Open this example in the calculator and change any input.

Formula

\(T = \frac{2T_k}{s/s_k + s_k/s}, \quad s_k = s_n\left(\lambda + \sqrt{\lambda^2 - 1}\right)\)

Variables

Symbol Meaning SI unit
\(P\) Rated output W
\(f\) Supply frequency 1/s
\(p\) Number of poles -
\(n_r\) Rated speed 1/s
\(\lambda\) Breakdown torque / rated torque -
\(n\) Speed of interest 1/s
\(n_s\) Synchronous speed 1/s
\(s_n\) Rated slip -
\(T_n\) Rated torque N·m
\(s_k\) Breakdown slip -
\(n_k\) Breakdown speed 1/s
\(T\) Torque at the speed of interest N·m
\(T_{st}\) Starting torque by Kloss (s = 1) N·m

Method and standards

Kloss formula.

Where it is used

  • Load acceleration and stall checks.
  • Variable-load drives.

Common mistakes

  • Using Kloss for starting torque of deep-bar rotors.
  • Using an odd pole number.

Assumptions and limits

  • Constant voltage and frequency; stator resistance neglected.

References

  • Kloss approximation of the induction motor torque curve

Questions and answers

What is breakdown torque?

The maximum torque the motor can develop; loading beyond it stalls the motor. Standard motors reach about 2–3 times rated torque.

Why does the Kloss starting torque look low?

Rotor resistance rises at standstill in deep-bar rotors, raising starting torque well above the simple curve.

What do the defaults represent?

An illustrative 37 kW, 4-pole, 50 Hz motor running at 1,475 rpm with breakdown torque 2.6 times rated, checked at 1,000 rpm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 4th ed. (McGraw-Hill, 2005), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.