Worked example
Example: 10 t water 20 to 80 °C in 2 h, U 800, 4 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid in the tank | 10.000 t |
| Specific heat of the liquid | 4.1800 kJ/(kg·K) |
| Starting temperature | 20.000 °C |
| Final temperature | 80.000 °C |
| Heat-up time wanted | 2.0000 h |
| Overall heat transfer coefficient of the coil | 800.00 W/(m²·K) |
| Steam pressure in the coil (absolute, saturated) | 4.0000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Coil area needed | 4.8211 m² |
| Steam used for the batch | 1,175.6 kg |
| Average steam flow | 587.81 kg/h |
| Peak steam flow at the start | 804.53 kg/h |
| Steam saturation temperature | 143.61 °C |
Open this example in the calculator and change any input.
Formula
\(A = \frac{m\,c_p}{U\,t}\ln\frac{T_s - T_0}{T_s - T_1} \qquad m_s = \frac{m\,c_p (T_1 - T_0)}{h_{fg}} \qquad \dot m_{s,0} = \frac{U A (T_s - T_0)}{h_{fg}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m\) | liquid mass | kg |
| \(c_p\) | liquid specific heat | J/(kg·K) |
| \(T_0\) | start temperature | K |
| \(T_1\) | final temperature | K |
| \(t\) | heat-up time | s |
| \(U\) | overall coefficient | W/(m²·K) |
| \(p_s\) | steam pressure | Pa |
| \(A\) | coil area | m² |
| \(m_s\) | steam for the batch | kg |
| \(\bar{\dot m}_s\) | average steam flow | kg/s |
| \(\dot m_{s,0}\) | peak steam flow | kg/s |
| \(T_s\) | steam saturation temperature | K |
| \(h_{fg}\) | latent heat | J/kg |
Method and standards
Unsteady batch heating with a condensing medium at constant temperature and constant U, integrated exactly; steam properties from IAPWS-IF97.
Where it is used
- Process water and chemical tanks.
- Oil storage heating.
- Jacketed reactors.
Common mistakes
- Sizing the trap on average instead of peak flow.
- Ignoring tank heat losses.
- Using a U for agitated liquid in a still tank.
Assumptions and limits
- Well-mixed liquid; condensate leaves saturated; no losses.
- The coil is at the steam pressure entered. A control valve ahead of the coil lowers the pressure and the steam temperature in the coil: enter the pressure in the coil, not the supply pressure.
References
- IAPWS-IF97
- Batch heating with constant U (Kern)
Questions and answers
What coil heats 10 t of water from 20 to 80 °C in 2 hours with 4 bar(a) steam?
4.82 m² at U 800 W/m²K; 1176 kg of steam (588 kg/h average, 805 kg/h at the start).
Why is the peak higher than the average?
The liquid is coldest at the start, so the temperature difference and heat flow are largest then.
What U should I use?
From the coil supplier or a heat transfer calculation; agitation raises it a lot.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.