FireCADCalc

Steam Flow through a Vent, Orifice or Leak

Steam flow through a start-up vent, restriction orifice or leak from the upstream pressure and the opening size, with the choked-flow check.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Start-up vent 40 mm from 66 bar(a) / 485 °C to atmosphereLeak 3 mm hole, saturated steam 10.5 bar(a)Orifice 20 mm, 3 bar(a) saturated to 2.5 bar(a) (not choked)

About 0.6–0.65 for a sharp-edged orifice or hole, 0.8–0.9 for a short pipe or valve, 0.95–0.98 for a rounded nozzle.
1.3 for superheated steam; 1.135 for dry saturated steam (Zeuner).

Results

Steam flow252.39kg/h
Choked (1 = yes)0
Critical (choking) downstream pressure1.7323bar
Critical pressure ratio0.57743
Specific volume upstream0.60579m³/kg
Area of the opening314.16mm²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Start-up vent 40 mm from 66 bar(a) / 485 °C to atmosphere. The inputs, in the units selected above:

InputValue
Upstream pressure (absolute)66.000 bar
Steam conditionSuperheated at the temperature below
Steam temperature (superheated only)485.00 °C
Diameter of the opening40.000 mm
Discharge coefficient0.85000 -
Downstream pressure (absolute)1.0132 bar
Isentropic exponent of steam1.3000 -

Applying the formula below gives:

ResultValue
Steam flow29,472 kg/h
Choked (1 = yes)1.0000
Critical (choking) downstream pressure36.018 bar
Critical pressure ratio0.54573
Specific volume upstream0.050026 m³/kg
Area of the opening1,256.6 mm²

Open this example in the calculator and change any input.

Formula

\(r_c = \left(\frac{2}{k+1}\right)^{\frac{k}{k-1}} \qquad p_c = r_c\,p_0 \qquad A = \frac{\pi d^2}{4}\)

Choked (\(p_b/p_0 \le r_c\)):

\(\dot m = C_d\,A\,\sqrt{\frac{k\,p_0}{v_0}}\left(\frac{2}{k+1}\right)^{\frac{k+1}{2(k-1)}}\)

Not choked, with \(r = p_b/p_0\):

\(\dot m = C_d\,A\,\sqrt{\frac{2\,p_0}{v_0}\cdot\frac{k}{k-1}\left(r^{2/k} - r^{(k+1)/k}\right)}\)

Variables

Symbol Meaning SI unit
\(p_0\) upstream pressure, absolute Pa
\(\text{state}\) dry saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(d\) diameter of the opening m
\(C_d\) discharge coefficient –
\(p_b\) downstream pressure, absolute Pa
\(k\) isentropic exponent of steam –
\(\dot m\) steam flow kg/s
\(\text{choked}\) 1 when the flow is choked –
\(p_c\) critical downstream pressure Pa
\(r_c\) critical pressure ratio –
\(v_0\) specific volume upstream m³/kg
\(A\) area of the opening m²

Method and standards

Isentropic flow of a gas with constant exponent k through a nozzle, with the upstream specific volume from FireCAD's IAPWS-IF97. k = 1.3 for superheated and 1.135 for dry saturated steam are the classical values (Zeuner).

Where it is used

  • Estimating steam lost through vents, leaks and open drains.
  • Valuing steam leak repairs.
  • Sizing start-up vents.

Common mistakes

  • Using gauge pressure as absolute.
  • Ignoring choked flow at high pressure ratio.
  • Assuming a round hole when the leak is a crack.

Assumptions and limits

  • Steam treated as a gas with a constant isentropic exponent. This is an approximation; it is not compared here with a homogeneous-equilibrium calculation. Dry saturated steam turns wet as it expands, and Zeuner's 1.135 is an empirical exponent for that wet expansion.
  • k should match the steam state; a mismatch is flagged.
  • Upstream velocity neglected (opening small against the pipe).
  • Not a safety-valve calculation: relieving capacities are certified to the pressure-vessel code.

References

  • Isentropic nozzle flow (Shapiro; Perry’s Chemical Engineers’ Handbook)
  • IAPWS R7-97(2012) IF97

Questions and answers

How much steam does a leak lose?

A 3 mm hole in a 10.5 bar(a) saturated steam line passes about 31 kg/h (0.0086 kg/s) with a discharge coefficient of 0.8: about 250 t of steam a year.

What is choked flow?

When the downstream pressure is below about 58 % of the upstream pressure (55 % for superheated steam), the steam reaches sonic velocity in the opening and the flow no longer depends on the downstream pressure.

Which discharge coefficient?

About 0.6–0.65 for a sharp-edged hole or orifice plate, 0.8–0.9 for a short pipe or open valve, close to 1 for a well-rounded nozzle.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.