FireCADCalc

Steam Velocity in a Pipe

Velocity of saturated or superheated steam in an existing pipe from flow, pressure, temperature and inside diameter, with specific volume from IAPWS-IF97.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: 10 t/h saturated at 10 bar g in DN150 sch 40 (154.1 mm)40 t/h at 45 bar(a) 400 °C in 202.7 mm2 t/h at 3 bar g in DN80 (77.9 mm)

DN150 schedule 40 is 154.1 mm inside; DN100 schedule 40 is 102.3 mm.

Results

Steam velocity22.303m/s
Volume flow2,590.9m³/h
Specific volume0.064773m³/kg
Density15.438kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h saturated at 10 bar g in DN150 sch 40 (154.1 mm). The inputs, in the units selected above:

InputValue
Steam flow10,000 kg/h
Steam pressure (shown as gauge)10.000 bar g
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Pipe inside diameter154.10 mm

Applying the formula below gives:

ResultValue
Steam velocity26.396 m/s
Volume flow1,772.3 m³/h
Specific volume0.17723 m³/kg
Density5.6423 kg/m³

Open this example in the calculator and change any input.

Formula

\(\dot V = \dot m\,v_s \qquad v = \frac{\dot V}{\pi D_i^2/4} \qquad \rho = \frac{1}{v_s}\)

Variables

Symbol Meaning SI unit
\(\dot m\) steam flow kg/s
\(p\) steam pressure Pa
\(\text{state}\) saturated or superheated –
\(T_s\) steam temperature K
\(D_i\) inside diameter m
\(v\) velocity m/s
\(\dot V\) volume flow m³/s
\(v_s\) specific volume m³/kg
\(\rho\) density kg/m³

Method and standards

Continuity with IAPWS-IF97 specific volume.

Where it is used

  • Checking existing mains after load growth.
  • Noise and erosion complaints.
  • Choosing control valve and meter sizes.

Common mistakes

  • Using nominal diameter.
  • Using gauge pressure as absolute.
  • Forgetting the lower pressure at the far end.

Assumptions and limits

  • Dry steam; velocity at the stated pressure only. Wet steam cannot be entered.
  • The 60 m/s warning is a screening level of this page, not a cited limit, and applies to both states; saturated mains are usually kept lower.
  • The pressure is shown as gauge in every unit system (bar g, kg/cm² g, psig).

References

  • IAPWS-IF97

Questions and answers

How fast does 10 t/h of saturated steam at 10 bar g move in DN150?

26.4 m/s in 154.1 mm bore (specific volume 0.177 m³/kg).

What velocity is right?

Your piping specification sets it; saturated mains are usually kept lower than superheated lines to limit erosion by droplets.

Why does velocity rise along a main?

Pressure falls, so specific volume rises.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.